Owner`s manual

NOTE: Ensure the GFCI is properly installed. Failure
to do so may result in spa malfunction or damage
which is not warranted. Ground Fault Circuit Interrupt-
ers are available from your Marquis Spas dealer.
! !
! !
!
AA
AA
A
TTENTIONTTENTION
TTENTIONTTENTION
TTENTION The Epic, Reward
and Destiny models are equipped with a GFCI Trip
Test that must be performed to assure safety and
allow proper spa function.
AUTOMATIC TEST: Approximately 24 hours follow-
ing startup, the spa will trip the GFCI, testing it to
insure it is functioning properly (do not call your
dealer; this is a signal that the spa is wired correctly).
After the trip test is complete, reset the GFCI as per
the manufacturer’s instructions and the spa will
function normally.
-OR- MANUAL TEST: The installer can manually
initiate the GFCI Trip Test at start up with a button
sequence on the control panel.
1. Press TEMP+, then JETS 1, then SPA LIGHT.
2.Press TEMP+ repeatedly until “gFC” is displayed,
then press JETS 1.
3.Press TEMP+ until “Gt.n” is displayed, then press
JETS 1 to initiate the test.
The GFCI should trip within several seconds and the
spa should shut down. After the trip test is complete,
reset the GFCI as per the manufacturer’s instructions
and the spa will function normally. If the test does not
trip theGFCI, manually shut down the power and
verify that a GFCI breaker is installed and that the
circuit, GFCI, and spa are wired correctly. Restore
power to the spa and verify the function of the GFCI
with its own test button. Reset the GFCI and repeat
the GFCI Trip Test.
After passing the GFCI trip test, subsequent GFCI
trips indicate a ground fault or other unsafe condition,
requiring the power to the spa to be shut off. You
can verify a successful test by navigating to the “gFC”
item as described above, pressing JETS 1 and then
pressing TEMP+ until you see “gS.P”, a code that
signifies “GFCI Status – Passed”.
WARNING: The GFCI Trip Test does NOT
take the place of locating, testing, and reset-
ting the GFCI on a regular basis to verify its
function.
If the spa is to be rewired, moved, or resold, the GFCI
Trip Test should be reset so it will test the new GFCI.
The “GFCI status – Passed” must be cleared before
the test can be run.
PAGE 14
installation instructions
MARQUIS SPAS