Certificate
Note 10 - The switch employes quick-connect terminals. They have been evaluated for use with solid and/or solder dipped stranded conductors,
No. 10 AWG.
Note 2 - For Cat. Nos. 1830 and 1835, the suitability of the steel spring as a current-carrying part in the pilot light portion of the switch, shall be
determined in the end-use.
Note 3 - The reversing switch has not been evaluated and should be investigated for compliance with the end-use product standard.
Note 4 - The quick-connect terminals have been investigated with a suitable female connector attached to No. 12 AWG wire. The suitability of
non-Recognized connector or other size wire shall be determined in the end-use application.
Note 5 - This switch is to be used with Marquardt switches Cat. No. 1293 (rated 6 A-125 V ac, 1/6 hp-125 V ac), Cat. No. 1297 (rated 6 A-125 V
ac, 1/4 hp-125 V ac, 5 A-250 V ac, 1/2 hp-250 V ac) and Lucerne switches, Cat No. TRM256 (rated 6 A-125 V ac), Cat No. TSCR-256 (rated 6
A-125 V ac). They each employ a built-in interlock at the trigger to prevent making and breaking current.
Note 6 - The screw-down wire binding terminals have not been investigated. The suitability of these terminals shall be determined in the end-use
application.
Note 7 - The supply source of the bulb circuit was not evaluated during the investigation of the switch. The suitability of this feature shall be
determined in the end-use application.
Note 8 - The performance of the remote actuated version (suffix RMTE) is dependent upon the combination of (1) the length of the extension rod
and (2) the distance between the Recognized Component Switch and the remote actuator button. The suitability of this combination should be
determined in the end product.
Note A - The switches are not considered relampable.
Note A2 - The function of the Unidirectional or Bidirectional Transient Voltage Suppressor Diode shall be evaluated for compliance with the end-
use Standard within the end product.
Note B - Type 1703.3402; Each pole has a special rating: 1st pole 5A 110-250Vac, 2nd pole 0.3A 15Vdc, 3rd pole 5A 110-250Vac, 4th pole 20A
15Vdc
Note C5 - Switch 2711.9xxx was tested with AWG14 wires. The leads (AWG26) connected to the PWB assembly and the four pin connector shall
be evaluated within the end product.
Note C7 - UL61058-1 - The declared thermal current for RM 10.5(10.5) is 3A.
Marking: Company name or trademark
, , , catalog, model or part number,
electrical ratings and the Recognized Component Mark, on the product or on the smallest unit container in which the product is packaged.
Last Updated on 2014-09-24
Questions? Print this page Terms of Use Page Top
© 2014 UL LLC
When the UL Leaf Mark is on the product, or when the word "Environment" is included in the UL Mark, please search the UL Environment
database for additional information regarding this product's certification.
The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured
under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up
Service. Always look for the Mark on the product.
UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide
Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non-
misleading manner, without any manipulation of the data (or drawings). 2. The statement "Reprinted from the Online Certifications Directory with
permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the
following format: "© 2014 UL LLC".
Page 38 of 38WOYR2.E41791 - Switches, Appliance and Special Use - Component