Certificate

*G3 - UL61058-1 - IPX7 testing was compelted on the complete switch without an end product enclosure. The switch gasket (seal) to the end
product enclosure is evaluated in the end product testing.
*Noe B4 - UL61058-1 - The tests wre conducted with wire size 16AWG, stranded only.
*Note 4 - UL61058-1 - the solder type terminal has evaluated the solerability of 260C.
*Note A - UL61058-1 - When mounted in accordance with the manufacturers instruction, this switch get a protection degree of IP40.
*Note A1 - UL61058-1 - These switches employ an integral potentiometer. The investigation was limited to the switching function of the switch.
The insulating materials and spacings of the integral potentiometer should be investigated for compliance with the end-use product standard.
*Note B - UL61058-1 - The tests were conducted with wire size 12AWG only, except the R-M rating. The tests for the R-M rating has been
condcted with 1mm2.
*Note B1 - The tests for rating R-M 13(12)A were conducted with wire size 18AWG on load side and 16AWG on line side, stranded only.
*Note B2 - UL61058-1 - The tests were conducted with wire size 18AWG on load side and 16AWG line side, stranded only.
*Note B3 - UL61058-1 - The tests for rating 4<13A were conducted with wire size 18AWG on load side and 16AWG on line side, stranded only.
*Note B5 - UL61058-1 -The tests were conducted with wire size 1mm2, stranded only.
*Note B6 - UL610581 - The tests were conducted with wire size 2.5mm2.
*Note C - UL61058-1 the heating test with the contacts in series to the SSD were tested with the contacts short before bypass the SSD with the
declared thermal current. In the end-use application the heating test should be conducted under the declared cooling conditions.
*Note C1 - UL61058-1 - The declared thermal current is 4A.
*Note C2 - UL61058-1 - The declared thermal current is 5.5A.
*Note C3 - UL61058-1 - If provided with a "Unindirectional or Bidirectional Transient Voltage Suppressor Diode" conected to the motor terminals,
the function shall be evaluated for compliance with the end-use Standard within the end product.
*Note C4 - Switch 2711.888x has may a customer specific battery terminal and a female connector at the motor wire leads. Both terminals shall
be investigated in the end use application.
*Note D10 - UL61058-1 - Change Over Switch type 1202, described in this report can be optional mounted on this switch 1298.
*Note D11 - UL61058-1 - Change Over function has been evaluated for no load switching only. Temperature test has been conducted with 13A as
declared under electrical ratings. the change over switch can be mounted as accessory on switches where also declared. The switch has been
evaluated for a voltage of 250 Vac and 127 Vac, 50/60 Hz.
*Note D12 - UL61058-1 - Dust ring is optional provided.
*Note D13 - UL61058-1 - Brake contact path to be evaluated in end application.
*Note D14 - UL61058-1 - The soldering terminals were tested for iron soldering only.
*Note D15 - UL61058-1 - The switch was sitched off over the integrated coil at rate of 6 operations/min (5sec=ON, 15sec=OFF).
*Note D16 - UL61058-1 - As the design allows the switches are operted at a rate of: 1sec ON/19sec OFF making: actuated mechanically,
braking: actuated by remote function.
*Note D2 - UL61058-1 - The soldering terminals wre tested for solder bath soldering only.
*Note D3 - UL61058-1 - Only appear to switch rated 16A GP, 250 Vac. Heating tests after 6K cycles have been done with wire size AWG No. 12.
*Note D4 - UL61058-1 - Switches with continuous contact.
*Note D5 - UL61058-1 - Only appear to switch 16A resistive, 250 Vac and to 16A GP, 250 Vac. Switches may be provided by a coil to open the
switch by an electrical impulse (remote off function). The functionality has not een investigated and shall be evaluated in the end use application.
*Note D6 - UL61058-1 - the wire set was not part of this investigation and shall be investigated in the end use application.
*Note D7 - UL61058-1 - the standard rotating reversing switch has not been investigated for "Making" or "Breaking" current. It is attached to the
switch as accessory and has no impact of the switching function. The suitability of the combination must be determined in accordance with the
end-product requirements.
*Note D8 - UL61058-1 - The potentiometer has not been evaluated.
*Note D9 - UL61058-1 - Switch is rated 2<13(13). The heating test withthe contacts in series to the SSD were tested withthe contacts short
before bypass the SSd with the declared thermal current. In the end use application the heating test should be conducted under the declared
cooling conditions. This is a tool switch with mechanical contacts with serial and parallel to the Solid state Switching Device (SSD).
*Note E3 - UL61058-1 - Brak contact path to be evaluated in end application.
*Note F1 - UL61058-1 - These are lighted switches maybe employing a lamp. The lamp life should be evaluated when required by the end-use
product Standard.
*Note G1 - UL61058-1 - IP4X for accessible parts and enclosure of the end product enclosure when mounted or installed according to the
manufacturers directions. Internal parts were not evaluated for IP ratings and must be considered in the end product.
*Note G2 - UL61058-1 - IP6X testing was completed on the complete switch without an end product enclosure. Under IP Category 1 (pressure
difference). The switch gasket (seal) to the end product enclosure is evaluated in the end product testing.
*Note G4 - UL61058-1 - IP67 for complete switch only if provided with integrated potted wires and sealing at actuator side.
*Note G5 - UL61058-1 - IP67 for accessible parts if sealing is provided only at actuator side and switch gasket (seal) to the end product
enclosure is evaluated in the end product testing. Internal parts were not evaluated for IP ratings and must be considered in the end product.
*Note G6 - UL61058-1 - The masimum current for these switches with integrated flexible/stranded potted wires with a minimum cross section of
AWG20 or 0.5mm2 or 0.5mm2 shall be Imax. 10A and for AWG18 or 0.75mm2 shall be IMax 12A.
*Note H1 - UL61058-1 - The minimum wire temperature for the 16(16) rated switch shall be 130C.
Note 1 - This switch has been investigated for use only as a voltage selector.
Page 3
7
of 38WOYR2.E41791 - Switches, Appliance and Special Use - Component
21.10.201
4
http://database.ul.com/cg
i
-
b
in/XYV/template/LISEXT/1FRAME/showpage.html?na
m
...