Certifications
ANNEX TO ENEC CERTIFICATE 71-106704 page 1 of 8
DEKRA Certification B.V. Meander 1051, 6825 MJ Arnhem P.O. Box 5185, 6802 ED Arnhem, The Netherlands
T +31 88 96 83000 F +31 88 96 83100 www.dekra-certification.com Company registration 09085396
SPECIFICATION OF THE CERTIFIED PRODUCT
Product data
Product
:
Rocker and toggle switches
Trade name(s)
:
MARQUARDT
Type(s)/model(s)
:
1800., 1801., 1802., 1803., 1804., 1805., 1806., 1808., 1809.,
1811., 1812., 1813., 1814., 1818., 1819., 1821., 1822., 1823.,
1824., 1828., 1829., 1850., 1852., 1855., 1858., 1881. and
1883.
Type reference
:
common type (C.T.)
Type of switch
:
incorporated
Rated voltage
:
250 V~
Contact opening
:
-
full disconnection
- micro disconnection (pattern nos. 4 and 4/2)
Class
:
for class II appliances
Degree of protection
:
IP40
Degree of pollution
:
3
Category to heat and fire
:
750 °C and 850 °C
Insulating material
:
tracking resistant (250 V)
Rated impulse withstand
voltage
:
2500 V
Material group
:
IIIa
Terminals
:
-
solder terminals,
- PCB terminals
- tab terminals (2,8 x 0,8 mm and 4,8 x 0,8 mm)
- screw terminals
Description
:
body and actuating member of thermoplastic material
Markings
:
trade name, type
reference, electrical ratings and
temperature limit on the base
Product data – type 1800.
Type of switch
:
rocker switch
Rated current
:
10(4) A and 6(4) A
Circuit to be controlled
:
resistive and motor
Pattern no.
:
1
Temperature limit
:
T100/55
Number of cycles
:
-
10.000 operating cycles for 10(4) A
- 50.000 operating cycles for 6(4) A
Design
:
optional provided with pilot lamp
Series resistor of pilot lamp
:
120
-
330 Kohm
Product data – type 1801.
Type of switch
:
rocker switch, which
makes momentary or continuous contact
Pattern no.
:
1
Rated current
:
6(4) A, 8(8) A, 10(4) A, 12(4) A, 5/50 A and 5/70 A
Pattern no.
:
1(N.O.)
Rated current
:
4(2) A, 6(4) A and 10(4) A
Pattern no.
:
1(N.C.)
Rated current
:
4(2) A and 10(4) A
Temperature limit
:
T100/55
Circuit to be controlled
:
-
resistive and motor
- resistive and capacitive
Number of cycles
:
-
50.000 operating cycles for 6(4) A and 8(8) A
- 10.000 operating cycles for 4(2) A, 10(4) A 12(4) A,
5/50 A and 5/70 A