User manual
9
15-Channel Operation
(continued)
Channel Function Value Description
13
Prism Rotation 000
–
127
Indexed position, 0° (000) to 360° (127)
128
–
189
Counterclockwise prism rotation, fast (128) to slow (189)
190
–
193 Stop at current position
194
–
255
Clockwise prism rotation, slow (194) to fast (255)
14
Macro Functions 000
–
007 No function
008
–
023 Automatic movement 1
024
–
039 Automatic movement 2
040
–
055 Automatic movement 3
056
–
071 Automatic movement 4
072
–
087 Automatic movement 5
088
–
103 Automatic movement 6
104
–
119 Automatic movement 7
120
–
135 Automatic movement 8
136
–
151 Sound-active movement 1
152
–
167 Sound-active movement 2
168
–
183 Sound-active movement 3
184
–
199 Sound-active movement 4
200
–
215 Sound-active movement 5
216
–
231 Sound-active movement 6
232
–
247 Sound-active movement 7
248
–
255 Sound-active movement 8
15
Control Functions
All functions are executed
after 2 seconds.
000
–
049 No function
050
–
059 Blackout during pan/tilt or colo/gobo change
060
–
069 Disable blackout during pan/tilt or colo/gobo change
070
–
079 Blackout during pan/tilt
080
–
089 Disable blackout during pan/tilt
090
–
099 Blackout during color change
100
–
109 Disable blackout during color change
110
–
119 Blackout during gobo change
120
–
129 Disable blackout during gobo change
130
–
139 No function
140
–
149 Reset pan/tilt
150
–
169 Reset color/gobo/focus/prism
170
–
199 No function
200
–
209 Reset all
210
–
255 No function