User manual
INSTALLATION
• Switch off appropriate mains fuse and master switch!
• Where present, take the wall switch out of the wall box.
• Disconnect all wires from the switch.
• Connect the live (brown) and load wire (black) to the terminals of
the LW12 as described in figure A.
• Replace your normal make/break contact switch by a momentary
switch.
• Connect a load wire (brown) to the momentary switch (CAUTION:
In the interest of safety and to make the device work properly, this
load wire HAS TO be from the same group).
• Connect a black wire to the output of the switch. Connect the
other end of this black wire to the input K of the LW12
MicroModule. See figure A.
• Place the module against the back of the wall box and replace the
switch inside the box.
• Switch on mains fuse and master switch.
1. Lamp
2. Neutral (blue)
3. Live (brown)
4. Momentary Switch
5. Load (black)
6. Switch input (black)
Figure A.
8 © MARMITEK