User manual
Resetting the LW12
When leaving the factory, the LW12 is set to the default address A1
en does not respond to the optional functions All Lights On/All Lights
Off/All Units Off. If the address and settings for the options "All lights
on/All lights off /All Units Off" aren’t known, the default address of
A1 can be set by applying power to the unit and sending the address
P16 to the unit twice (using any X-10 controller - i.e.: TM13 + RF
remote control).
This can either be just the address "P16" or "P16 On" or "P16 Off".
The commands must be sent within 30 seconds of applying power to
the unit. Setting the default address automatically cancels the options
"All Lights On", "All Lights Off" or "All Units Off".
Exiting the programming mode
Automatic: Wait for 1 minute. The device will then automatically exit
the program mode. Manually: To return to Run Mode: either send
"Address On", "Address Off" or press the key quickly (no more than
1. 5 seconds between key presses). After 5 key presses or "On/Off"
commands, the LW12 will start to respond, indicating that the unit is
back in Run Mode.
Detailed information on the type of switch
If the connected momentary switch is used, the status of the LW12
will change if the button is pressed for less than 2 seconds. If the
momentary switch is pressed for a longer duration, the LW12 will dim.
The module first dims all the way down and then back up.
10 © MARMITEK