Specifications

To program the TWA Event option:
1. From the Programming menu, select Communications, Comm.
Options, TWA Event Rept. [95414].
2. Select Enabled or Disabled.
10.8.2: TWA Time Report
If the TWA Time Report option is enabled, the last three digits of the TWA Event Report
are replaced with the amount of seconds programmed for the TC/VM Timeout – see
10.6.11: Telecontrol/Vocal Message Timeout. For example, if the TC/VM Timeout is
programmed as 120 seconds, the Contact ID event code that shall be sent for the TWA
Event Report shall be 606120.
To program the TWA Time Report option:
1. From the Programming menu, select Communications, Comm.
Options, TWA Time Rept. [95415].
2. Select Enabled or Disabled.
10.9: Event Options for Monitoring station Reporting
System events are divided into a number of different event groups. This division allows
you to enable or disable reporting or Two-Way Audio for a specific group of events.
The different event groups are as follows:
x Burglary [#1]
x Fire [#2]
x Open/Close (arm/disarm) [#3]
x Service [#4]
x Power [#5]
x Peripherals [#6]
x RF Jamming [#7]
x Medical [#8]
10.9.1: Event Reporting
You can enable or disable event reporting per Event Group. This allows you to filter the
type of events that are reported to the monitoring station.
To enable/disable reporting for an event group:
1. From the Programming menu, select Communications, Event Options
[955].
2. Select an Event Group.
3. From the event group’s sub-menu, select Report [#1].
4. Select Enabled or Disabled.
10.9.2: Restore Reporting
For each event group, you can determine whether restore messages shall be sent.
To enable/disable restore reporting for an event group.
1. From the Programming menu, select Communications, Event Options
[955].
2. Select an event group.
3. From the event group’s sub-menu, select Report Restore [#2].
ProGuard800™ -77-