4. Select either Enabled or Disabled.
1
Fire zones always activate the siren regardless of what is programmed for this option.
If the bell is disabled for Panic zones, this also disables all forms of alarm indication from
the on-board keypad in the event of a Panic alarm.
If the Bell option is enabled for Environmental or Flood zones, the system sounds trouble
tones from the keypad.
7.6.4: Chime
When Chime is enabled, triggering the zone when the system is disarmed causes the
internal siren to chime.
To program the Chime option:
1. From the Programming menu, select Devices, Sensors [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Chime [#06]; the zone’s current
Chime setting is displayed.
4. Select either Enabled or Disabled.
7.6.5: Force Arm
Force arming enables you to arm the system when the system is not ready. For example,
a door that is protected by a magnetic contact is open. You may arm the system on
condition that the zone is defined as Force Arm enabled. This door must be closed by
the end of the Exit delay otherwise an alarm is generated. If the magnetic contact’s zone
is defined as Force Arm disabled, the system will not be ready to arm until you close the
door.
To program the Force Arm option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Force Arm [#07]; the zone’s current
Force Arm setting is displayed.
4. Select either Enabled or Disabled.
1
For the Force Arm feature to function, you must also enable Force Arming in System
Options (see 9.3.1: Forced Arm).
7.6.6: Swinger
A zone defined as Swinger enabled can generate only a limited number of alarms
during a specific time period. The Swinger setting is defined in System Options – see
9.1: Swinger Setting.
To program the Swinger option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Swinger [#08]; the zone’s current
Swinger setting is displayed.
4. Select either Enabled or Disabled.
1
Do not enable the Swinger option for zones that are always active (Panic, Medical, Fire,
24-hr, Gas, Flood and Environmental zones).
-48- © MARMITEK