Specifications
ProGuard800™ -47-
This section explains the sections of programming exclusive to sensors. For information
on registration, descriptor editing and deletion, see sections 7.1, 7.2 and 7.3,
respectively.
7.6.1: Zone Type
The zone type defines the type of alarm the system generates when the sensor is tripped.
To program a zone type:
1. From the Programming menu, select Devices, Zones [911].
2. Select the sensor you want to program.
3. From the sensor’s sub-menu, select Zone Type [#02].
4. Select one of the following zone types:
x Normal
x Entry/Exit
x Follower
x Panic
x Medical
x Fire
x 24Hr
x 24Hr-X (future option)
x Gas
x Flood
x Environmental
x No Motion
x Not Used
For a detailed explanation on the function of each zone type, see
Appendix D:
Zone Types
7.6.2: Arm Set
The Arm Set option allows you to define the arming methods in which the zone is included.
To program the Arm Set option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the sensor you want to program.
3. From the zone’s sub-menu, select Arm Set [#03]; the zone’s current
Arm Set setting is displayed.
Arm Set Description
1 (F) The zone is included in Full arming.
2 (P) The zone is included in Part arming.
3 (PE) The zone is included in Perimeter arming.
Table 7.1 Arm Set Options
4. Use the keys 1, 2 and 3 to toggle the current setting.
5. Press 3 when the desired setting is displayed.
1
It is not necessary to program this option for Panic, Medical, Fire, 24Hr, Gas, Flood and
Environmental zones.
7.6.3: Bell
Each zone can be programmed to activate the siren when triggered or to generate a
silent alarm where only a message is sent to the monitoring station.
To program the Bell option:
1. From the Programming menu, select Devices, Zones [911].
2. Select the zone you want to program.
3. From the zone’s sub-menu, select Bell [#05]; the zone’s current Bell
setting is displayed.