Instruction Manual
INSTALLATION & OPERATION MANUAL 14-0268 REV 9 (07/22)
PAGE
6
OF 20
SIRIUS II -
Congratulations on purchasing the Market Forge Sirius II. The Sirius II is a single compartment countertop or two
The cooking chamber of the SIRIUS II is treated with a scratch resistant, non-stick surface. A drain from the rear of the
steamer is provided for easy safe draining.
propane gas.
INTRODUCTION
I
CAUTION
Do not use utensils, steel wool, or other harsh abrasives to clean your steamer. Scratching of the non-stick surface
and stainless steel casing may occur.
As with any cooking process, or with any piece of commercial cooking equipment, there are potential hazards to both
the operator and the piece of equipment if care is not taken. In designing the Sirius II steamer, safety features have
been built in to protect against many of these potential hazards, but TRAINING OF EACH OPERATOR AND CAREFUL
ADHERENCE TO ALL WARNINGS ARE NECESSARY TO ENSURE THE SAFETY OF USERS.
Diagnostic Sensor Shut-o: The thermostat controller has a built in diagnostic feature that will automatically shut down
the burner if the sensor probe fails, which will avoid overheating.
High Limit Shut-o: If the steamer runs dry the burner will shut down.
Overow
WARNING
will void the warranty.
High Water Sensor: Two water level sensors are located on the lower backside of the steamer. The lower sensor
that both sensors are kept clean so that the stainless part is shiny.
WARNING
the steamer.
Door Open Safety Switch: There is a safety switch built into the door frame that shuts down the burner, fan and lights
ORDER FOR THE STEAMER TO FUNCTION. IF STEAM IS ESCAPING, DOOR IS NOT PROPERLY SHUT AND MAY
AFFECT COOK TIMES, PRODUCT QUALITY AND WATER CONSUMPTION.