Instruction Manual
INSTALLATION & OPERATION MANUAL 14-0268 REV 9 (07/22)
PAGE
4
OF 20
SIRIUS II -
SERVICE CONNECTIONS
WATER SUPPLY AND DRAIN SPECIFICATIONS
Each single compartment has one rear drain connection
4” clearance left mandatory, right and rear is recommended.
Location near a floor drain is recommended.
NOTES
Good quality water feed is the responsibility of the owner. Water quality must be within the following general guidelines.
TDS: 40-125 ppm Hardness: 35-100 ppm pH: 7.0 - 8.5 Silica: <13 ppm Chlorides: <25 ppm Chlorine: <0.2 ppm Chloramine: <0.2 ppm
The best defense against poor water quality is a water treatment system designed to meet your water quality conditions.
Pressure: 25(min)-50(max) PSI Connections: Trough drain: 1/2 MNTP Drain out: 1” FNPT Water: 3/4” male garden hose
Appliance to be installed with backflow protection according to federal, state or local codes.
The drain piping must consist of temperature resistant material, greater than 160°F, and be of adequate diameter not to cause flow
restriction. Improper materials may deform and cause restrictions, thus affecting performance.
oducts
Each compartment requires separate electrical & water connection.
The manufacturer reserves the right to modify materials and specifications without notice.
GAS PRESSURE AND CONNECTIONS
Natural - 3.5” WC required, not to exceed 13.5”
Propane - 9” WC required, not to exceed 13.5”
Gas pipe size: 1/2” NPT required as a minimum
24.00 [610]
19.00 [483]
6.00
[152]
20.00 [508]
FRONT VIEW
3.88
[98]
4.75 [121]
2.00 [51]
Sirius II-4
26.25 [667]
Sirius II-6
33.25 [845]
Sirius II-4
15.38 [391]
Sirius II-6
22.38 [568]
30.75 [781]
28.75 [730]2.00
[51]
17.75 [451]
Pull out service
drawer
Door in open
position
2.00
[51]
22.00 [559]
SIDE VIEW
4.75
[121]
REAR VIEW
5
[127]
6.50
[165]
6.25
[159]
Steam
Vent
Flue
1.50
[38]
2.00
[51]
21.00
[533]
8.50
[216]
3.25
[83]
Water in
Gas in
1/2” NPT
Pans Sirius II-4 Sirius II-6
12” x 20” x 2.5” 4 6
12” x 20” x 4” 2 4
12” x 20” x 6” 1 2
Sirius II-4 Sirius II-6
Voltage 120V 120V
27,000* 27,000*
Gas NPT 1/2” 1/2”
SPECIFICATIONS AND COMPARTMENT PAN CAPACITY
DIMENSIONS ARE IN INCHES [MM]
FRONT VIEW SIDE VIEW REAR VIEW