SIRIUS II -
Recommended Water Quality: Refer to Service Connections in this Manual for the recommended water quality criteria.
NOTICE
Water level probes will not sense water level if steamer is connected to a de-ionized water or reverse osmosis system.
WARNING
The water may be very hot. It is advisable to allow the water to cool down before draining. Leaving the door open
will aid cooling.
WARNING
WARNING
Rear Drain
However, one 90° elbow is shipped with the steamer to be used as needed. The drip trough located under the door is
plumbed to the main drain internally.
The drain piping must consist of temperature resistant material, greater than 160°F, and be of adequate diameter not to
Customer supplies plumbing, however, one 90° elbow is supplied with the steamer to be used as needed. The drip trough
located under the door is plumbed to the main drain internally.
Overow Pipe
done by turning the base of the leg. Use the top of the steamer casing as a reference. It is recommended to use a level to
ensure proper installation.
I
facing to the front of the steamer. Repeat this process for the rack mounted on the other side. These racks are designed
to be removed easily for cleaning.
Once your steamer is in place and properly leveled, plumbed and wired, test unit to make sure it is functioning properly.