Operating instructions
17
SECTION 5 ASSEMBLY
STERILMATIC OPEN STAND
Market Forge Sterilmatic Stand can be supplemented with an Optional
Stand for utility use where maximum compactness is desired.
The sturdy, stainless steel unit is equipped with adjustable leg
extensions which allow the unit to be installed and leveled over existing
contours in the floor .
The open design lends itself to maximum sanitary conditions because
of the ease with which periodic cleaning can be done.
Though simple in design and appearance, the sterilmatic stand is the
ideal arrangement for mounting in that it allows secondary air to
circulate
STERILMATIC OPEN STAND WITH CONDENSER
Market Forge can provide the open stand with an optional steam condenser system for use
where steam exhaustion into the room is undesirable.
The condenser is automatically controlled by the thermostat. The normal factory thermostat
setting is 130° (54° C). The open under-shelf of the stand gives added utility. providing a
handy tabouret for utensils and access for drainage of water from the sterilizing chamber.
PARTS LIST FOR CONDENSER WITH OPTIONAL STAND
ITEM PART NO. 50 Hz DESCRIPTION
1 10-4653 10-4653 Thermostat
2 10-4035 10-7074 3/8" Solenoid
3 10-5731 10-5731 1/2" Water Stop Valve
4 95-2106 95-2106 Water Injection Assembly
5 95-1680 95-1680 Shelf
STERILMATIC DOOR ASSEMBLY
The Door of the Sterilmatic has been engineered to establish a positive method of sealing the
steam pressure within the sterilizing cylinder. As steam pressure builds up within the cylinder,
the door seal will tend to become more positive.
However, the door should be adjusted to make a good initial seal between the door gasket
and the door opening without the added assistance of internal cylinder steam pressure with
the simple action of securing the door handle down in a locked position, the door gasket
should be sufficiently compressed against the door opening, all the way around to prevent
any steam leakage from occurring.