Operating instructions
7
InstallatIon
Pan Supports and Bafes
5. Position the second pan support rack into the cavity
and slide the other mounting tab onto the rack at
bend while the pan support rack is not on the mount-
ing studs. Hang the pan support by placing the rear
key-way slot onto the rear mounting stud and slide
the rack until the slot sits on the mounting stud. When
this is done correctly the front mounting stud will be in
position to place the front key-way slot. Slide the rack
down into its correct position.
6. Place the Perforated Water Bafe so that it sits on the
bottom of the inside of the sterilizer chamber.
Perforated Water Baffle
Figure 8
CAUTION
Do not cover the holes in the Perforated Water
Bafe by using it as a shelf. This will result in
a disrupted ow of steam.