Owner`s manual

2
SERVICE CONNECTIONS
Direct Connected
S Steam Supply - 3/4” (19mm) NPT, 15 P.
S.I (1.0 kg/cm
2
) minimum; 30 P.S.I (2.1
kg/cm
2
) maximum.
HW Hot Water - 3/8” (10mm) OD tubing to
hot water for kettle ll faucet.
CW Cold Water - 3/8” (10mm) OD tubing to
cold water for kettle ll faucet.
D Drain - Pipe full 2”
NPT (51mm) to ush
oor drain. Do not make solid connec-
tion to drain.
CR* Condensate Return - 1/2”
I.P.S. (13mm)
connection for condensate return from
kettle when specied.
EC* Electrical Controls - 115 volts AC, 60 Hz,
40 watts, 1/2” (13mm) conduit connec-
tion or equivalent. Use wire suitable for
at least
90
O
C. Draws less than 1 Amp
with power lift.
* Optional
INTRODUCTION
NOTES:
Pressure-reducing valve is required if incoming pres-
sure exceeds 30 PSI (2.1 kg/cm
2
).
Recess area for kettle draw-off (dotted line) must be
kept free of all piping and connections.
PVC and CPVC pipe are not acceptable materials for
drains.
Separate height for 25-, 40-, and 60-gallon kettles.
MT-60
MT-25
MT-40