Specifications
3
InstallatIon
Service Connections
SERVICE CONNECTIONS
S Steam Supply - 3/4” (19mm) NPT, 15 P.S.I (1.0 kg/
cm2) minimum; 30 P.S.I (2.1 kg/cm2) maximum.
HW Hot Water - 3/8” (10mm) 3/8” (10mm) NPT for hot
water to faucet. Hot water line will have a maximum of
50 PSI (3.5kg/ cw2) and a minimum of 25 PSI (1.8 kg/
cw2) water pressure (Water may be filtered).
CW Cold Water - 3/8” (10mm) NPT for cold water to faucet.
Cold water line will have a maximum of 50 PSI (3.5kg/
cw2) and a minimum of 25 PSI (1.8 kg/cw2) water
pressure.
D Drain - Pipe full 2” NPT (51mm) to flush floor drain. Do
not make solid connection to drain.
CR* Optional Condensate Return - 1/2” NPT (13mm)
connection for condensate return from kettle when
specified.
EC* Electrical Controls - 115 volts AC, 60 Hz, 40 watts,
1/2” (13mm) conduit connection or equivalent. Use wire
suitable for at least 90°C. Draws less than 1 Amp with
power lift.
* Optional
NOTES:
Pressure-reducing valve is required if incoming pressure exceeds
30 PSI (2.1 kg/cm2).
Recess area for kettle draw-off (dotted line) must be kept free of
all piping and connections.
PVC and CPVC pipe are not acceptable materials for drains.
Separate height for 25 and 40 gallon kettles.
DIMENSIONS ARE IN INCHES [MM]
HW
S
CW
EC
D
CR
66.5
[1689]
Maximum
Height
22 [559]
21 [533]
6 [152]
43 [1092]
38 [965] MT-40
33 [838] MT-25
28 [711]
7 [197]
MT-40
POUR PATH
6 [152]
8 [203] MT-40
10 [254]
36 [914]
CR
4 [102]
4 [102]
D
DRAW OFF AREA
EC
S
2.88
[73]
15 [381]
5 [127]
15 [381]
2.5 [64]
6.38 [162]
1.75 [45]
33 [838]
13 [330]
13.88 [352]
11.5
[292]
HW
CW
Figure 1