Installation Instructions

//Data2/MarineSync-Sales Marketing/Approved Technical Docs/RUM
9
When connecting more than one meter to the RUM Transponder, use terminal #8, #10 and #11.
If the utility meter provides more than one output resolutions (10, 100, 1000), determine the
appropriate resolution for your application (fig 2) and connect to the RUM meter input. If you need
assistance selecting a resolution, contact MarineSync.
Figure 2
Decals have been provided (fig 3) to identify the Transponder ID installed at each pedestal. Use the
corresponding “input” decal to label the receptacle or side of the pedestal connected to the
transponder. Place the decal in a visible location and ensure the decal is adhered in a protected location
for future reference.
It is extremely important to properly label the pedestals. The Transponder ID and the meter inputs are
used during setup, troubleshooting and system maintenance.
Figure 3
Output Resolutions
Isolated 10 = 100 Pulses per kWh
Isolated 100 = 10 Pulses per kWh
Isolated 1000 = 1 Pulse per kWh