Installation Instructions
//Data2/MarineSync-Sales Marketing/Approved Technical Docs/RUM
7
Preparing the Transponder
Remove the RUM splash cover using a #1 Phillips Screw Driver. Use caution not to lose the stainless
hardware.
To remove the terminal connector from the transponder, firmly pull the desired connector away from
the transponder.
As required, use 16-22AWG tinned copper wire for field wiring; strip field wiring to .20 to .24 inches.
Wiring the Transponder
Only use MarineSync supplied AC/DC power supply.
Locate the “Monitoring” connector on the RUM transponder. Fig 2
Figure 2
Figure 2
Connect the positive lead from (12-24 VDC) power supply to terminal #5. Fig 3
Connect the negative lead from the power supply to terminal #6. Fig 3
Figure 3
E471429