User Manual
15
1. Unplug water heater power cord from the electrical outlet.
2. Drain and remove the water heater. (see page 13)
3. Remove six screws retaining the bottom panel of the water heater and remove
the panel. Locate the high limit reset button.
4. Depress the small red button in the center of the junction box, replace the
bottom panel and place the water heater back into service.
NOTE: A lower temperature setting saves energy and reduces the risk of scalding.
CALL A TECHNICIAN IF THE HIGH LIMIT NEEDS TO BE RESET FREQUENTLY.
CAUTION
DO NOT TAMPER WITH THE RESET BUTTON TO OVERRIDE OVERHEATING SHUT DOWN.
WARNING
PROBLEM: WATER DOES NOT GET HOT
1. Make sure the power supply is on and working.
2. If light does not turn on, check that the reset button is pushed in; follow steps from
previous section.
3. If the indicator light is illuminated, but water temperature does not get hot at the sink, test
for a plumbing cross over as follows; shut off cold water supply to water heater and open hot
water tap. There should be no water owing. Any continuous ow indicates a cross over
which will affect the temperature and will need to be corrected.
4. If there is no crossover, then replace the heating element (see previous sections).
PROBLEM: INDICATOR LIGHT NOT ON
1. If the light does not turn on, but water gets hot, check for faulty bulb.
2. Check reset button; follow steps from previous section.
11. TROUBLESHOOTING