User Manual
09
c) Install the expansion bolt into the drilled hole. Hang the unit utilizing the screws supplied.
WATER SUPPLY
Connect the cold water inlet supply.
Note: Use white Teon tape at all threaded water connections.
- The cold water inlet joint is ½” NPT threaded pipe.
- The water inlet should be connected by using exible heavy duty tubing or rigid PVC pipe. If
you choose exible tubing, you will need a ½” threaded male to ½” hose barb adapter. Tubing
should be secured with properly sized hose clamps. Rigid pipe should be ½” male threads.
Teon tape should be employed with any threaded ttings.
- The inner diameter of the inlet pipe (including the valve) should not be less than 3/8”. Larger
diameter pipe is acceptable with the appropriate adapters to reduce to ½” at the inlet joint.
- The cold water valve must be installed inline with the water inlet pipe.
- Always ush a new unit with water to clear out any collected deposits or debris prior to
installation. The supplied screen lter must be correctly installed in the cold water inlet to
prevent mineral deposits from your water supply from building up in the unit's water valve
assembly. After ushing with cold water and conrming that there is no residue in the pipe,
install the rubber gasket and tighten the water inlet joint.
Drawing 04
Washer
Nut
Expansion Screw
Heater Case
29"
8"