c) Install the expansion bolt into the drilled hole. Hang the unit utilizing the screws supplied.
WATER SUPPLY
Connect the cold water inlet supply.
Note: Use white Teon tape at all threaded water connections.
- The cold water inlet joint is ½” NPT threaded pipe.
- The water inlet should be connected by using exible heavy duty tubing or rigid PVC pipe. If
you choose exible tubing, you will need a ½” threaded male to ½” hose barb adapter. Tubing
should be secured with properly sized hose clamps. Rigid pipe should be ½” male threads.
Teon tape should be employed with any threaded ttings.
- The inner diameter of the inlet pipe (including the valve) should not be less than 3/8”. Larger
diameter pipe is acceptable with the appropriate adapters to reduce to ½” at the inlet joint.
- The cold water valve must be installed inline with the water inlet pipe.
- Always ush a new unit with water to clear out any collected deposits or debris prior to
installation. The supplied screen lter must be correctly installed in the cold water inlet to
prevent mineral deposits from your water supply from building up in the unit's water valve
assembly. After ushing with cold water and conrming that there is no residue in the pipe,
install the rubber gasket and tighten the water inlet joint.
Drawing 04
Washer
Nut
Expansion Screw
Heater Case
29"
8"