User Manual
06
- Do NOT install the water heater in a sealed room or in a room with poor air circulation.
- You MUST install the exhaust pipe to properly discharge the exhaust gases.
- Do NOT block the exhaust pipe or the air inlet at any time. This can cause incomplete
combustion and can lead to gas poisoning.
- When the water heater is in use, do NOT touch the body of the heater. Touch the knobs only,
as the body of the heater can become very hot to the the touch.
- Prevent scalds! While using the water heater, always check the water temperature
and adjust as needed before use.
WARNING! There is water contained in the coils of your water heater at all times. If your water
heater is exposed to freezing temperatures, the water in the coils could freeze, causing a break
in the heat exchanger of the unit, or the supply and return lines. This kind of damage will result
in water running freely into the space where the water heater is located, with can cause
ooding. If your water heater is installed in a geographic location that sees very low sustained
temperatures, you MUST install a backow preventer on your heater's vent pipe. This will
ensure that cold air cannot fall down into the water heater and cause freezing damage. DO NOT
install this water heater where it may be subjected to a freeze. If your water heater is in an area
where freezing is a possibility, you must turn off the water to the heater and drain it of any water
by using the valve stem at the bottom of the unit and disconnecting the warm water line. Leave
the valve stem and the warm water line disconnected until you intend to use the water heater.
1. Water - controlled automatic ignition:
When water ow is detected, heating is provided immediately with a double ignition device. The
ame is sensed by ions. This sensitive control makes the unit easy and convenient to operate.
2. Auto - cut off protection:
The auto-cut-off protection will shut off the gas supply immediately if the ame goes out for any reason.
3. Energy savings:
The advanced combustion system comes with a Winter/Summer switch. In winter, when
incoming water temperatures are lower, the winter setting increases the size of the ame to
compensate with extra heating. In summer, when incoming water temperatures are higher,
the summer setting reduces the ame.This provides more comfort and energy savings in the
form of lower gas consumption in warmer months.
4. FUNCTIONS AND FEATURES