Use and Care Manual

16
*With and without LCD panels.
NOTE: If your gas model features an LCD panel, the digital display will indicate the outgoing
water temperature.
This information is intended as a guideline based on typical residential environments.
Temperature increases will vary depending on the environment in which the heater is used.
Variables such as very low incoming water temperature or higher than average gas pressure
can result in higher temperature increases. Higher incoming water temperature or lower than
average gas pressure can result in lower temperature increases. ALWAYS test the water with
your hand to conrm suitable temperature before use.
Temperature increases listed are based on use of the water heater under optimal conditions
with an incoming water temperature of 48ºF. Variable factors such as incorrect or imperfect
installation or warmer incoming water temperature may yield different results.
9. TECHNICAL PARAMETERS
10. TEMPEARURE INCREASE CHART
* No need for electricity, starts with pulse ignition, powered by 2 D cell batteries.
Hot Water Outlet per Minute
Heat Loss
Exhaust Discharge Mode
Ignition
Energy Efciency
Width x Height x Depth
Weight
Aplicable Water Pressure
Flue Duct Type
54% - 87%
3.6 - 145.0 PSI / 0.25 - 10 bar
2D Cell Battery Powered (not included)
16 LPM / 4.2 GPM
111,903 BTU/h
16,5" x 27,9" x 8,2"
29 lbs
Related Gas Pressure (PSI)
0.25 up to 0.5 PSI (NG) & 0.4 (LPG)
Gas Type Liquid Propane Gas or Natural Gas
Activation Flow Rate
Maximmum Flow Rate 4.3 GPM
10 PSI
TECHNICAL SPECIFICATIONS GAS 16L
*Highest gas setting: set for Winter/High
*Lowest gas setting: set for Summer/Low
Gas
Setting
GA16L
MODEL
Highest
Lowest
0.5
GPM
1.0
GPM
1.5
GPM
2.0
GPM
2.5
GPM
2.7
GPM
3.0
GPM
3.5
GPM
4.0
GPM
4.3
GPM
-
88º
143º
44º
95º
29º
71º
22º
57º
18º
52º
16º
48º
15º
41º
13º
36º
11º
33º
10º
TEMPERATURE INCREASE PER GPM