Congratulations! You've just purchased a new Marey ECO180 tankless water heater and will soon begin to enjoy the benefits of “going tankless.” Take the time to thoroughly read and understand this safety and installation manual in its entirety before you attempt to install your new ECO180 tankless water heater, as it contains important safety tips and instructions. Please carefully read all instructions and warnings.
If your water heater requires a reset, be sure to TURN OFF THE BREAKER prior to resetting the unit. 8. DO NOT switch the heater on if you suspect that it may be frozen. Wait until you are sure that it has completely thawed out. Resetting your unit without turning off the breaker can result in personal injury and damage to your water heater. 9. Before taking a shower, feel the outlet hot water temperature with your hand to make sure it is suitable for showering to avoid getting scalded. 10.
6. Dry-heating thermal cut-off. In case of dry heating, the electricity will be cut off and the screen display will display an E4 code. 7. Micro-computer features an automatic electricity and water consumption calculating function. 8. Reads temperature in both Fahrenheit and Celsius. Marey heating element is made from a single piece of cast aluminum, so there will never be water leakage nor the electric leakage in the heating chamber.
Buttom Case TECHNICAL SPECIFICATIONS ECO180 Power Voltage Frequency 18Kw Max. Amperage Load 75A Min. Required Circuit Breaker Size 2x50A Recommended Wire Size 2x8 AWG copper Max. Temp. Increase at 1.5 GPM 81ºF Min. Water Flow to Activate the Unit Temp. Scope 0.85 GPM / 3.2 LPM 86~127ºF Water Connections Installation Control Height x Depth x Width 3/4" NPT Vertical Mounted Manual 16" x 11" x 3,5" Weight 18.3 lbs 240V 60Hz Control Board Display Screen Up On/Off Down Display Screen Temp.
NOTE: Installation must be in compliance with the National Electrical Code and your local electrical and plumbing codes. Front and back of the appliance (please see Fig. 06). 1. Do not install the unit in a room where there is a chance of freezing. 2. DO NOT install this water heater near tinder, volatile or flammable substances, or near a strong magnetic field. The unit must only be mounted in a VERTICAL position near the water fittings. 3.
Hold the back bracket hanger in position against the wall in the desired hanging location. Check to make sure that the bracket is level. Mark the wall where the three mounting holes should be located. Drill holes of ¼” diameter in the marked locations. If you are on a stud, screw the bracket directly into the wall. If you are not on a stud, insert the plastic anchor in the hole, and secure the bracket using the screws supplied (Fig. 09). Fig. 09 Fig.
Connect the power cable at the lower right side of the unit to the terminal block. Each wire in the cable is labeled to correspond with spaces in the terminal block. Make sure that you plug the appropriately labeled wire into the corresponding space on the terminal block. Note that the unit will be connected to two circuit breakers (Fig. 13). Reattach the cable for the LCD panel if disconnected and reinstall the front cover using the screws and washers previously removed. (Fig. 14). Fig. 14 Fig.
Important Notes About Water Connections: 1. All water pipe must comply with national and applicable state and local water pipe codes. 2. The unit should be connected directly to the main water supply. Flush pipe with water to remove any debris or loose particles. 3. All connections to the unit should be ¾” NPT. Larger pipe can be connected but the appropriate adapters must be used. 4. Please remember to install rubber seal rings at the connections.
Possible Causes Problems Corrective Actions NORMAL MAINTENANCE 1. Inlet and outlet fittings leaking A. Fittings not tight B. Rubber washer worn-out A. Tighten fittings. B. Change rubber washer. Note: Do not attempt to repair this water heater yourself. Call a service person for assistance. Always turn off the breaker before working on the unit. 2. LED no signal A. Power not connected. B. LCD damaged. C. LCD not connected to PCB. A. Connect power to the unit. B. Change LCD. C.
At Marey, we pride ourselves on the excellence of our customer service and support team. Please visit our website to get to know more about other Marey products. Please feel free to contact us if you have any questions about our products, warranty service, or if you need assistance installing a unit. We also strive for continuous improvement,sowewelcome your comments, feedback and suggestions. 1-512-332-2229 customerservice@marey.