EXPLODED VIEWTECHNICAL PARAMETERS
TEMPERATURE INCREASE CHART
TECHNICAL SPECIFICATIONS
GAS 5 FLOW
5L / min
Liquid Propane or Natural Gas 
2 PSI -145 PSI 
0.29 KPA - 0.479 KPA 
Flue Duct Type 
1/2" NPT
2D Cell Battery Powered (not included) 
84% 
* No need for electricity, starts with pulse ignition, powered by 2 D cell batteries.
Hot Water Output per Minute 
Heat Loss 
Activation Pressure 
Maximum Flow Rate 
Dimensions 
Weight 
Gas Type 
Safe Operating Water Pressure 
Min & Max Gas Inlet Pressure 
Exhaust Discharge Mode 
Water Connections
Ignition 
Energy Efficiency 
34,120 BTU/h 
2 PSI
1.32 GPM - 5 LPM
17.1" X 11.27" X 4.23" 
10 lbs 
This information is intended as a guideline based on typical residential environments. Temperature increases 
will vary depending on the environment in which the heater is used. Variables such as very low incoming 
water temperature or higher than average gas pressure can result in higher temperature increases. Higher 
incoming water temperature or lower than average gas pressure can result in lower temperature increases. 
ALWAYS test the water with your hand to conrm suitable temperature before use. 
*Highest gas setting:
set Winter/High 
*Low
est gas setting:
set for Summer/Low
Temperature increases listed are based on use of the w
ater hea
ter under optimal 
conditions with an incoming wat
er temperature of 48°F. Variable factors such as 
incorrect or imperfect installation or warmer incoming water temperature may yield 
dierent results. 
GAS 10 FLOW
10L / min
Liquid Propane or Natural Gas 
2.9 PSI - 72.5 PSI 
1.7 KPA - 35 KPA 
Flue Duct Type 
1/2" NPT
2D Cell Battery Powered (not included) 
84% 
68,240 BTU/h 
2.9
 PSI
2.64 GPM - 10 LPM
28.74" X 15.74" X 9.44" 
24 lbs 
TEMP. INCREASE PER GPM
GAS 5 FLOW
Highest  Lowest Highest  Lowest
GAS 10 FLOW
 GPM
0.5
1.0
1.5
2.0
2.5
2.7
3.0
126˚F
64˚F
43˚F
32˚F
-
-
-
34˚F
17˚F
11˚F
9˚F
-
-
-
-
100˚F
67˚F
50˚F
40˚F
37˚F
30˚F
68˚F
34˚F
23˚F
17˚F
14˚F
13˚F
9˚F