560/1562 Barcode Scanner Setup barcodes included. Version 1.
Copyright © 2009~2011 CIPHERLAB CO., LTD. All rights reserved The software contains proprietary information of CIPHERLAB CO., LTD.; it is provided under a license agreement containing restrictions on use and disclosure and is also protected by copyright law. Reverse engineering of the software is prohibited. Due to continued product development this information may change without notice.
IMPORTANT NOTICES FOR USA This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.
FOR HAND-HELD PRODUCT WITH RF FUNCTIONS The 1560/1562 unit (FCC ID: Q3N-1560) complies with FCC radiation exposure limits set forth for uncontrolled environment and meets the FCC radio frequency (RF) Exposure Guidelines in Supplement C to OET65. The unit has very low level of RF energy that it is deemed to comply without testing of specific absorption ratio (SAR). The 3656 unit (FCC ID: Q3N-3656) complies with FCC radiation exposure limits set forth for an uncontrolled environment.
RELEASE NOTES Version Date Notes 1.10 Aug 31, 2011 New: “Auto Power Off Ignoring Scan Mode” is added. Sections involved are: 1.09 1.08 1.07 1.06 May 25, 2011 Mar. 11, 2011 Jan. 10, 2011 Nov. 30, 2010 Renamed section 1.1.1 “Turn on/off the Scanner” Modified section: 1.1.2 “Power Economy”. Adjusted new Connection” section: 1.1.3 “Power Economy vs. WPAN Modified: 3656+USB+Adaptor issue Modified: 1.
1.05 Apr. 09, 2010 Modified: 1.1.2 Auto Power Off & Power-Saving Modified: 2.1.3 Keyboard Settings — BT HID supports “Alphabets Layout” Modified: 2.1.5 HID Character Transmit Mode Modified: 2.5.2 Baud Rate — add setup barcode for 4800 bps (100100) Modified: 2.5.2 Baud Rate — change default baud rate to 115200 bps Modified: 2.6.1 Activate USB HID & Select Keyboard Type — add Turkish Modified: 2.6.
CONTENTS IMPORTANT NOTICES ...................................................................................................................... - 3 For USA .......................................................................................................................................... - 3 For Canada .................................................................................................................................... - 3 For Hand-held Product with RF Functions .......................
1560 Series Barcode Scanner User Guide 1.4 Beeper ....................................................................................................................................... 34 1.4.1 Beeper Volume................................................................................................................. 35 1.4.2 Good Read Beep .............................................................................................................. 36 1.4.3 Low Battery Alarm ............................
1560 Series Barcode Scanner User Guide 2.5.1 Activate RS-232 Interface ............................................................................................... 83 2.5.2 Baud Rate.........................................................................................................................83 2.5.3 Data Bits ........................................................................................................................... 84 2.5.4 Parity ...............................................
1560 Series Barcode Scanner User Guide 4.5.1 Start/Stop Transmission................................................................................................129 4.5.2 Verify Check Digit ...........................................................................................................129 4.5.3 Transmit Check Digit......................................................................................................130 4.5.4 Standard/Full ASCII Code 39 ..........................................
1560 Series Barcode Scanner User Guide 5.2.1 Select a Set for Character Substitution ........................................................................157 5.2.2 Symbologies for Character Substitution (All 3 Sets) ....................................................158 5.3 Prefix/Suffix Code...................................................................................................................164 5.4 Code ID.....................................................................................
1560 Series Barcode Scanner User Guide Example ....................................................................................................................................222 KEYBOARD WEDGE TABLE ..............................................................................................................223 Key Type & Status .........................................................................................................................224 Key Type...........................................
INTRODUCTION CipherLab’s 1560 Series Barcode Scanners are specifically designed to answer your mobile demands. The versatile scanners are designed to help accelerate productivity while lowering the total cost of ownership. Intensive data collection jobs are made easier with fast, accurate barcode scanning in various working environments, especially in small businesses.
1560 Series Barcode Scanner User Guide GETTING FAMILIARIZED WITH 1560/1562 AND 3656 INSTALLING THE BATTERY TO 1560/1562 When you first receive the package, the rechargeable battery is stored separately from the scanner. Insert the battery into the scanner first so that it can be charged when sitting in the Auto-Sense stand. Note: Any improper handling may reduce the battery life. 1) Hold the scanner still and insert the battery into the battery compartment at the bottom of the scanner.
Introduction SETTING UP 3656 Capable of charging 1560/1562, the 3656 stand is specifically designed for the scanner to communicate with a host computer wirelessly. The connection between the scanners and 3656 is made easy and reliable. Refer to 3.1.1 Connect to 3656. The 3656 stand is also an Auto-Sense stand when used with the scanner set to Auto-Sense mode. Two LED indicators are provided for power and communications status.
1560 Series Barcode Scanner User Guide --- Blue, flashing Connected with the scanner (Fast flash at 1 Hz) Red, solid Blue, flashing Failed to send data to host via USB Virtual COM (Fast flash at 1 Hz) Red, flashing --- Enter Download Mode 4 Enter Setup
Introduction CHARGING THE BATTERY VIA 3656 The battery may not be charged to full for shipment. When you first receive the package, you will need to charge the battery to full before using the scanner. When using the RS-232 cable, it takes approximately 5 hours to charge the battery to full (from the power adaptor). Note: Battery charging stops when the temperature drops below 0°C or exceeds 40°C. It is recommended to charge the battery at room temperature (18°C to 25°C) for optimal performance.
1560 Series Barcode Scanner User Guide CHARGING THE BATTERY VIA CHARGER The battery charger is provided for charging the battery only. You may purchase the charger separately. It takes approximately 3 hours to charge the battery to full. Note: Battery charging stops when the temperature drops below 0°C or exceeds 40°C. It is recommended to charge the battery at room temperature (18°C to 25°C) for optimal performance. 1) Insert the battery. 2) Lock the battery.
Introduction INSIDE THE PACKAGE The items included in the package may be different, depending on your order. Save the box and packaging material for future use in case you need to store or ship the scanner. Barcode Scanner (1560 or 1562) BT Base (3656) Rechargeable Li-ion battery Product CD Note: The CD-ROM includes this manual and Windows-based ScanMaster software for configuration, as well as the USB Virtual COM driver.
1560 Series Barcode Scanner User Guide SYMBOLOGIES SUPPORTED Most of the popular barcode symbologies are supported, as listed below. Each can be individually enabled or disabled. The scanner will automatically discriminate and recognize all the symbologies that are enabled. Refer to Chapter 4 Changing Symbology Settings for details of each symbology.
Introduction GS1 DataBar (RSS) GS1 DataBar Omnidirectional (RSS-14) Disabled GS1 DataBar Truncated Disabled GS1 DataBar Stacked Disabled GS1 DataBar Stacked Omnidirectional Disabled GS1 DataBar Limited (RSS Limited) Disabled GS1 DataBar Expanded (RSS Expanded) Disabled GS1 DataBar Expanded Stacked Disabled 9 Update
1560 Series Barcode Scanner User Guide 10 Enter Setup
QUICK START The configuration of the scanner can be done by reading the setup barcodes contained in this manual or via the ScanMaster software. This section describes the procedure of configuring the scanner by reading the setup barcodes and provides some examples for demonstration. Configuration Mode 1. Hold down the trigger about 2 seconds to turn on the scanner. It will respond with a long beep and its LED will come on-off shortly. 2. Have the scanner read the “Enter Setup” barcode.
1560 Series Barcode Scanner User Guide Working Mode Upon powering up, the 1560/1562 scanner will try to establish a connection with 3656 or a computer with Bluetooth® wireless technology. Refer to Chapter 3 – Setting up a WPAN Connection for details. The connection between the scanners and 3656 is made easy and reliable. Note: If RS-232, USB Virtual COM or BT SPP is selected for output interface, the host can directly send serial commands to configure the scanner. For example, run HyperTerminal.
Quick Start ENTER CONFIGURATION MODE For the scanner to enter the configuration mode, you must have it read the “Enter Setup” barcode, which can be located at the bottom of almost every even page of this manual. The scanner will respond with six beeps and its LED indicator will become flashing red after reading the barcode. Enter Setup For configuring scanner parameters, see “Read a Setup Barcode” below.
1560 Series Barcode Scanner User Guide DEFAULT SETTINGS SAVE USER SETTINGS AS DEFAULTS For the scanner to keep the customized settings as user defaults, you must have it read the “Save as User Defaults” barcode. This is a normal setup barcode, and the scanner will respond with two beeps (low-high tone). After reading the “Update” barcode, the current settings will be saved as user defaults.
Quick Start READ A SETUP BARCODE CONFIGURE PARAMETERS For most of the scanner parameters, only one read is required to set them to new values. The scanner will respond with two beeps (low-high tone) when each parameter is set successfully. But for a number of special parameters, multiple reads are required to complete the setting. In this case, the scanner will respond with a short beep to indicate it needs to read more setup barcodes.
1560 Series Barcode Scanner User Guide The example below shows how to save your settings as “User Default” so that you may restore user defaults at a later time: Steps Action User Feedback if Successful 1 Power on the scanner… The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. 2 Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will be flashing red.
Quick Start The example below shows how to set numeric parameters: Steps Action User Feedback if Successful 1 Power on the scanner... The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. 2 Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red. 3 Read a Setup barcode...
1560 Series Barcode Scanner User Guide The example below shows how to set string parameters: Steps Action User Feedback if Successful 1 Power on the scanner... The scanner will respond with a long beep (high tone) and its LED indicator will become solid red and go off quickly. 2 Enter the Configuration Mode… The scanner will respond with six beeps (high-low tone repeats three times), and its LED indicator will become flashing red. 3 Read a Setup barcode...
Quick Start LIST THE CURRENT SETTINGS The current settings of all scanner parameters can be sent to the host computer for user inspection. The listing includes pages as shown below. You can select the page of interest by having the scanner read the “List Page x” barcode. The scanner will respond with two beeps (low-high tone) and send the selected page to the host immediately.
1560 Series Barcode Scanner User Guide List settings regarding Editing Format 4 List Page 11 List settings regarding Editing Format 5 List Page 12 20 Enter Setup
Quick Start CREATE ONE-SCAN SETUP BARCODES The fact is most of the scanner parameters require only one read for setting new values. To facilitate configuring the scanner, you may create One-Scan setup barcodes for use.
1560 Series Barcode Scanner User Guide 22 Enter Setup
Chapter 1 UNDERSTANDING THE BARCODE SCANNER This chapter will guide you through the features of the barcode scanner and how it can function for you. IN THIS CHAPTER 1.1 Battery..................................................................... 1.2 Memory.................................................................... 1.3 LED Indicator ............................................................ 1.4 Beeper ..................................................................... 1.5 Send “NR” to Host ....
1560 Series Barcode Scanner User Guide 1.1.2 POWER ECONOMY The scanner features “Power-Saving”, “Auto Power Off” and “Auto Power Off Ignoring Scan Mode” giving consideration to the power issue that is generally critical for Bluetooth-enabled devices.
Chapter 1 Understanding the Barcode Scanner Note: Power-Saving won’t take effect when one of the following conditions is met: (1) the scanner has already established a BT HID/SPP connection, (2) the scanner is in the configuration mode, (3) the scan mode is set to Test, Continuous or Alternate Mode, (4) 1560 is in Auto-Sense mode and seated in the 3656 stand, or (5) the setting value of Power-Saving is greater than that of Auto Power Off. 1.1.2.
1560 Series Barcode Scanner User Guide Note: “Auto Power Off” will not take effect when one of the following conditions is met: (1) the scanner is in the configuration mode, or (2) 1560 is in Auto-Sense mode and seated in the 3656 stand. 1.1.2.3 AUTO POWER OFF IGNORING SCAN MODE This mode is intended only for Continuous Mode, Test Mode, and Alternate Mode. To force a scanner that is set to one of these three modes to automatically power off to save power, you need the following settings: 1.
Chapter 1 Understanding the Barcode Scanner 1.1.3 POWER ECONOMY VS. WPAN CONNECTION Before the scanner can communicate with the host computer, Bluetooth connection (or WPAN connection) needs to be established. The scanner’s power economy always accommodates itself to the establishment of the WPAN connection. The following describes how the scanner carries out power economy before and after the establishment of the WPAN connection: Before establishing a WPAN connection successfully… 1.
1560 Series Barcode Scanner User Guide try every 5 seconds to re-connect to the host unless you have the scanner read the “Reset Connection” barcode. For BT SPP Slave Mode, the scanner waits for the host to re-connect. With the use of 3656, the scanner tries to re-connect 3656 unless you turn off the scanner. For BT SPP Master Mode, the scanner resumes the connection with the host upon powering on again as long as the host application is running.
Chapter 1 Understanding the Barcode Scanner 1.2 MEMORY The collected data can be sent back to a host computer one by one via the WPAN connection or stored in flash memory when the scanner is set to Memory mode. 1.2.1 TRANSMIT BUFFER By default, transmit buffer is enabled and for use when the scanner is out of range. Upon reading a barcode successfully within range, the scanner responds with one short beep (high tone) and its LED indicator becomes solid green and goes off quickly.
1560 Series Barcode Scanner User Guide 1.2.2 MEMORY MODE The scanner keeps 512 KB flash memory for memory mode operation. When the scanner is in memory mode, it means any real-time connection established with the host is disabled. Enable *Disable Warning: No real-time connection is allowed unless the memory mode is disabled. Memory Data Delay You may set a delay between each data record while transmitting data back to the host.
Chapter 1 Understanding the Barcode Scanner 8 sec Send Data The 512 KB flash memory on the scanner can store up to 32,768 scans based on EAN-13 barcodes. When it is used up, the scanner will respond with two short beeps (high-low tone) as a warning. You are advised to send data to the host immediately by having the scanner read the “Send Data” barcode below. It will resume the previous WPAN connection with the host temporarily.
1560 Series Barcode Scanner User Guide 1.3 LED INDICATOR The triple-color LED on top of the scanner is used to provide user feedback. For example, the LED becomes solid red and goes off quickly upon powering on or running out of transmit buffer. You may tell the difference by the beeps – you will hear a long beep of high tone when powering on the scanner, and a long beep of low tone when the transmit buffer becomes full. Meaning Scanner LED Charging (On/Off ratio 0.5 s: 0.
Chapter 1 Understanding the Barcode Scanner 1.3.1 GOOD READ LED *Enable Good Read LED Disable Good Read LED 1.3.2 GOOD READ LED DURATION By default, the Good Read LED stays on for 40 milliseconds. Specify a value, ranging from 1 to 254 in units of 10 milliseconds. Good Read LED Time-out after 0.01~2.54 sec. (*40 ms) 1) Read the barcode above to specify the time interval before the Good Read LED goes off. 2) Read the “Decimal Value” barcode on page 227.
1560 Series Barcode Scanner User Guide 1.4 BEEPER The scanner has a buzzer to provide user feedback in various operating conditions.
Chapter 1 Understanding the Barcode Scanner 1.4.
1560 Series Barcode Scanner User Guide 1.4.
Chapter 1 Understanding the Barcode Scanner 1.4.3 LOW BATTERY ALARM By default, it will activate the beeper to give a warning when the battery charge gets low. In order to prevent data loss, you are advised to replace the battery immediately when you hear two short beeps (high tone).
1560 Series Barcode Scanner User Guide 1.5 SEND “NR” TO HOST The scanner can send the “NR” string to the host to notify the No Read event.
Chapter 1 Understanding the Barcode Scanner 1.6 SCAN MODES Different scan modes are supported – select the scan mode that best suits the requirements of a specific application. Refer to the comparison table below.
1560 Series Barcode Scanner User Guide 1.6.1 CONTINUOUS MODE The scanner is always scanning. After a successful decoding, the removal of barcode is required. It is not allowed to proceed to decode until the decoding delay time has passed. To decode the same barcode repeatedly, move away the barcode and put it back again and again for scanning. Note: Refer to “Delay between Re-read”. Continuous Mode Decoding Delay Set the time interval between each decoding. *Disable 0.5 sec 1 sec 2 sec 1.6.
Chapter 1 Understanding the Barcode Scanner 1.6.3 LASER MODE The scanner will start scanning once the trigger is held down. The scanning won’t stop until (1) a barcode is decoded, (2) the pre-set timeout expires, or (3) you release the trigger. Note: Refer to “Scanning Timeout”. *Laser Mode 1.6.4 AUTO OFF MODE The scanner will start scanning once the trigger is pressed. The scanning won’t stop until (1) a barcode is decoded, and (2) the pre-set timeout expires. Note: Refer to “Scanning Timeout”.
1560 Series Barcode Scanner User Guide 1.6.6 ALTERNATE MODE The scanner will start scanning once the trigger is pressed The scanning won't stop until you press the trigger again. Alternate Mode 1.6.7 AIMING MODE The scanner will aim at a barcode once the trigger is pressed, and start scanning when the trigger is pressed again within one second. The scanning won't stop until (1) a barcode is decoded, and (2) the pre-set timeout expires.
Chapter 1 Understanding the Barcode Scanner 1.6.8 MULTI-BARCODE MODE The scanner will be scanning as long as the trigger is held down, capable of decoding one single barcode, as well as multiple unique barcodes one at a time. While decoding a bunch of unique barcodes, if a barcode is decoded twice, its subsequent decoding will be ignored and the scanner is expecting another unique barcode. The scanning won't stop until you release the trigger.
1560 Series Barcode Scanner User Guide 1.7 SCANNING TIMEOUT Specify the scanning time interval (1~254 sec.; 0= Disable) when the scan mode is set to any of the following – Laser mode Auto Off mode Auto Power Off mode Aiming mode Scanner Time-out after 0~254 sec. (*10) 1) Read the barcode above to specify the time interval before the scan engine times out. 2) Read the “Decimal Value” barcode on page 227.
Chapter 1 Understanding the Barcode Scanner 1.
1560 Series Barcode Scanner User Guide 1.9 READ REDUNDANCY FOR ALL SYMBLOGIES Select the level of reading security. For example, If “No Redundancy” is selected, one successful decoding will make the reading valid and induce the “READER Event”. If “Three Times” is selected, it will take a total of four consecutive successful decoding of the same barcode to make the reading valid. The higher the reading security is (that is, the more redundancy the user selects), the slower the reading speed gets.
Chapter 1 Understanding the Barcode Scanner 1.10 ADDON SECURITY FOR UPC/EAN BARCODES The scanner is capable of decoding a mix of UPC/EAN barcodes with and without addons. The read redundancy (0~30 times) allows changing the number of times to decode a UPC/EAN barcode before transmission. The more redundancy you select, the higher the reading security is, and thus, the slower the reading speed becomes. You will have to compromise between reading security and decoding speed.
1560 Series Barcode Scanner User Guide 1.11 AUTO-SENSE MODE (1560 ONLY) This mode is only available when you want to seat the scanner in the Auto-Sense stand. When you enable this mode, it will force the scanner to apply Laser mode as the scan mode. However, it works slightly differently from the original Laser mode. Now the scanner will be expecting barcodes as long as it is seated in the Auto-Sense stand, as shown below. Whenever a barcode is brought within range, the scanner will be able to decode it.
Chapter 1 Understanding the Barcode Scanner When the ambient light is too dim to activate the sensor, you may have the scanner read the “High Sensitivity” barcode to improve performance. Starting from firmware version 1.23, it will emit scan beam every 300 milliseconds when “High Sensitivity” is enabled. High Sensitivity *Normal Note: If the ambient light is under 100 lux, we suggest that you either add lighting or use Continuous mode instead.
1560 Series Barcode Scanner User Guide 1.12 CCD SENSOR ALWAYS ACTIVE (1560 ONLY) This feature is used to keep the CCD sensor always active so that the scanner can decode more efficiently. However, you may disable it in order to save battery power. *Enable Disable 1.13 NEGATIVE BARCODES Normally, barcodes are printed with the color of the bars darker than that of the spaces. But for negative barcodes, they are printed in the opposite sense just like negative films.
Chapter 1 Understanding the Barcode Scanner 1.14 EFFECTIVE DECODING AREA By default, the effective decoding area is 100% covered by the scanned area. However, you may narrow down the decoding area to prevent reading the wrong barcode when a number of barcodes are printed closely. The scanner will only read barcodes that appear in the effective decoding area. Read the barcode “Centering On” and specify the percentage to narrow down the decoding area.
1560 Series Barcode Scanner User Guide 1.14.
Chapter 2 SELECTING OUTPUT INTERFACE In order to establish a proper connection between your computer and the scanner, we suggest that you follow these instructions – 1) Install the battery and hold down the trigger for about 2 seconds to turn on the scanner. 2) Have the scanner read the “Enter Setup” barcode to enter the configuration mode. 3) Have the scanner read the associated barcodes to activate the desired interface. See the following sections for output interfaces supported.
1560 Series Barcode Scanner User Guide 2.1 BT HID For BT HID, refer to Chapter 3 – Setting up a WPAN Connection for related connection settings. Run any text editor on your computer, and the scanned data will be transmitted to the computer.
Chapter 2 Selecting Output Interface 2.1.1 ACTIVATE BT HID & SELECT KEYBOARD TYPE When BT HID interface is activated, you will have to select a keyboard type to complete this setting. By default, BT HID is activated on the scanner, and the keyboard type is set to PCAT (US). Activate BT HID & Select Keyboard Type… 1) Read the barcode above to activate BT HID and select a keyboard type. 2) Read the “Decimal Value” barcode on page 227. Refer to the table below for the number of desired keyboard type.
1560 Series Barcode Scanner User Guide 2.1.2 RESET CONNECTION For BT HID, you can only have the scanner connected to one computer at a time. If you want to connect the scanner to another host, you must have it read the “Reset Connection” barcode so that the current connection record will be cleared. Then, the scanner will restart itself automatically. Go through the whole process in 3.2.3 Connect to Dongle to establish a new connection.
Chapter 2 Selecting Output Interface 2.1.3 KEYBOARD SETTINGS Alphabets Layout Digits Layout Capital Lock Type Capital Lock Setting Alphabets Transmission Digits Transmission Note: BT HID does not support these functions on PDAs – (1) Capital Lock Setting: Auto Detection (2) Digits Transmission: Numeric Key Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary.
1560 Series Barcode Scanner User Guide US Keyboard Style – Normal QWERTY layout, which is normally used in western countries. Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. French Keyboard Style – AZERTY French layout; see below for French Keyboard Style. Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters. German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style.
Chapter 2 Selecting Output Interface Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options Description Normal Depends on the [Shift] key or [Shift Lock] setting Lower Row For QWERTY or QWERTZ keyboard Upper Row For AZERTY keyboard *Normal Upper Row Lower Row Note: This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required.
1560 Series Barcode Scanner User Guide Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys.
Chapter 2 Selecting Output Interface *Capital Lock OFF 61 Update
1560 Series Barcode Scanner User Guide Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only. Ignore Case *Case-sensitive Refer to 5.1 Letter Case.
Chapter 2 Selecting Output Interface Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad. Numeric Key *Alphanumeric Key Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be “ON”. This setting is not supported on PDAs.
1560 Series Barcode Scanner User Guide 2.1.4 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay… (*0~254) 1) Read the barcode above to specify the inter-character delay.
Chapter 2 Selecting Output Interface 2.1.6 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host in batch. You may have the scanner read the “By Character” barcode to process data one character at a time. *Batch Processing By Character Note: “By Character” transmit mode is required when working with iPhone or iPad. 2.1.
1560 Series Barcode Scanner User Guide 2.2 BT SPP SLAVE For BT SPP Slave, refer to Chapter 3 – Setting up a WPAN Connection for related connection settings. 2.2.1 ACTIVATE BT SPP SLAVE MODE This is SPP Slave Mode. Activate BT SPP, Slave Mode 2.2.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface.
Chapter 2 Selecting Output Interface 2.2.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur.
1560 Series Barcode Scanner User Guide 2.3 BT SPP MASTER As a SPP master device, the scanner will be able to resume connection with the host upon powering on again, as long as the host application is running. If the scanner fails to resume connection, it will try every 5 seconds to re-connect to the host unless you have the scanner read the “Reset Connection” or “Restore System Defaults” barcode. For BT SPP Master, refer 3.2.2 Configure Related Settings for related connection settings.
Chapter 2 Selecting Output Interface Note: Read the “Set Connection” barcode first, and then the “MAC ID” barcode within 10 seconds. Instead of producing the “MAC ID” barcode, you may have the scanner read the setup barcodes for entering the MAC address. Have the scanner read the “Abort” barcode to cancel the operation at any time while reading setup barcodes for the MAC address.
1560 Series Barcode Scanner User Guide 2.3.2 INTER-FUNCTION DELAY By default, the inter-function delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every function code (0x01 ~ 0x1F) being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Function Delay… (*0~254) 1) Read the barcode above to specify the inter-function delay.
Chapter 2 Selecting Output Interface 2.3.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur.
1560 Series Barcode Scanner User Guide 2.4 KEYBOARD WEDGE VIA 3656 The Y cable allows you to connect the scanner via 3656 to the keyboard input port of PC and you may join the keyboard as well. The scanned data will be transmitted to the host keyboard port as if it is manually entered via the keyboard. For example, run a text editor on your computer to receive the data.
Chapter 2 Selecting Output Interface 2.4.1 ACTIVATE KEYBOARD WEDGE & SELECT KEYBOARD TYPE When Keyboard Wedge interface is activated, you will have to select a keyboard type to complete this setting. Activate 3656 Keyboard Wedge & Select Keyboard Type… 1) Read this barcode above to activate Keyboard Wedge and select a keyboard type. 2) Read the “Decimal Value” barcode on page 227. Refer to the table below for the number of desired keyboard type.
1560 Series Barcode Scanner User Guide 2.4.2 KEYBOARD SETTINGS Alphabets Layout Digits Layout Capital Lock Type Capital Lock Setting Alphabets Transmission Digits Transmission Alternate Composing Laptop Support Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary.
Chapter 2 Selecting Output Interface US Keyboard Style – Normal QWERTY layout, which is normally used in western countries. Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. French Keyboard Style – AZERTY French layout; see below for French Keyboard Style. Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters. German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style.
1560 Series Barcode Scanner User Guide Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting.
Chapter 2 Selecting Output Interface Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys.
1560 Series Barcode Scanner User Guide *Capital Lock OFF 78 Enter Setup
Chapter 2 Selecting Output Interface Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only. Ignore Case *Case-sensitive Refer to 5.1 Letter Case.
1560 Series Barcode Scanner User Guide Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad. Numeric Key *Alphanumeric Key Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be “ON”.
Chapter 2 Selecting Output Interface ALT Composing By default, Alternate key composing is disabled. Select [Yes] to allow emulating Alternate key code of a specific keyboard character. For example, [Alt] + [065] will be sent to host for the character “A” regardless the keyboard type you are using. Yes *No Laptop Support By default, laptop support is disabled. It is suggested to enable this feature if you connect the wedge cable to a laptop without an external keyboard being inter-connected.
1560 Series Barcode Scanner User Guide 2.4.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay… (*0~254) 1) Read the barcode above to specify the inter-character delay.
Chapter 2 Selecting Output Interface 2.5 RS-232 VIA 3656 Use the RS-232 cable to connect the scanner via 3656 to the serial port of PC, and connect the power supply cord. The associated RS-232 parameters must match those configured on the computer. You may run HyperTerminal.exe on your computer, and the scanned data will be transmitted to the computer.
1560 Series Barcode Scanner User Guide 4800 bps 2400 bps 1200 bps 600 bps 2.5.3 DATA BITS *8 bits 7 bits 2.5.
Chapter 2 Selecting Output Interface 2.5.5 STOP BIT 2 stop bits *1 stop bit 2.5.6 FLOW CONTROL By default, there is no flow control in use. Select the flow control (handshake) method. Options Description No No flow control Scanner Ready The scanner will activate the RTS signal upon powering on. After each good read, the scanner will then wait for the CTS signal to become active. Data will not be sent until the CTS signal becomes active.
1560 Series Barcode Scanner User Guide 2.5.7 INTER-CHARACTER DELAY By default, the inter-character delay is zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay… (*0~254) 1) Read the barcode above to specify the inter-character delay.
Chapter 2 Selecting Output Interface 2.5.9 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur.
1560 Series Barcode Scanner User Guide 2.6 USB HID VIA 3656 For USB HID, use the USB cable to connect the scanner via 3656 to the USB port of PC and connect the power supply cord. Run any text editor on your computer, and the scanned data will be transmitted to the computer. Warning: When the 3656 stand is solely on USB power, the current may be insufficient for it to function normally. You must connect the power supply cord.
Chapter 2 Selecting Output Interface 2.6.1 ACTIVATE USB HID & SELECT KEYBOARD TYPE When USB HID interface is activated, you will have to select a keyboard type to complete this setting. Activate 3656 USB HID & Select Keyboard Type… 1) Read the barcode above to activate USB HID and select a keyboard type. 2) Read the “Decimal Value” barcode on page 227. Refer to the table below for the number of desired keyboard type. 3) Read the “Validate” barcode on the same page to complete this setting.
1560 Series Barcode Scanner User Guide 2.6.2 KEYBOARD SETTINGS Alphabets Layout Digits Layout Capital Lock Type Capital Lock Setting Alphabets Transmission Digits Transmission Alphabets Layout By default, the alphabets layout is set to normal mode, also known as the standard English layout. Select French or German keyboard layout if necessary. The scanner will make adjustments when sending the "A", "Q", "W", "Z", "Y", and "M" characters according to this setting.
Chapter 2 Selecting Output Interface US Keyboard Style – Normal QWERTY layout, which is normally used in western countries. Select “Lower Row” for the “Digits Layout” setting for the upper row is for special characters. French Keyboard Style – AZERTY French layout; see below for French Keyboard Style. Select “Upper Row” for the “Digits Layout” setting for the lower row is for special characters. German Keyboard Layout – QWERTZ German layout; see below for German Keyboard Style.
1560 Series Barcode Scanner User Guide Digits Layout Select a proper layout that matches the alphabets layout. The scanner will make adjustments according to this setting. Options Description Normal Depends on the [Shift] key or [Shift Lock] setting Lower Row For QWERTY or QWERTZ keyboard Upper Row For AZERTY keyboard *Normal Upper Row Lower Row Note: This setting is to be used with the Character Substitution setting when support to certain keyboard types (languages) is unavailable but required.
Chapter 2 Selecting Output Interface Capital Lock Type & Setting In order to send the alphabets with correct case, the scanner needs to know the status of Caps Lock on the keyboard. Incorrect settings may result in reversed case of the alphabets being transmitted. Cap Lock Type Description Normal Normal type Capital Lock When enabled, the keys of alphabetic characters will be interpreted as capital letters. However, this does not affect the number or punctuation keys.
1560 Series Barcode Scanner User Guide *Capital Lock OFF 94 Enter Setup
Chapter 2 Selecting Output Interface Alphabets Transmission By default, the alphabets transmission is case-sensitive, meaning that the alphabets will be transmitted according to their original case, the status of Caps Lock on the keyboard, as well as the Capital Lock setting. Select [Ignore Case] to have alphabets transmitted according to the status of Caps Lock on the keyboard only. Ignore Case *Case-sensitive Refer to 5.1 Letter Case.
1560 Series Barcode Scanner User Guide Digits Transmission By default, the alphanumeric keypad is used for transmitting digits. Select “Numeric Keypad” if you wish to use the keys on the numeric keypad. Numeric Key *Alphanumeric Key Note: If you select “Numeric Keypad”, the Num Lock status of the physical keyboard should be "ON".
Chapter 2 Selecting Output Interface 2.6.3 INTER-CHARACTER DELAY By default, the inter-character delay is set to zero. Specify a value, ranging from 0 to 254 in units of millisecond, to match the computer response time of the keyboard interface. Such delay time is inserted between every character being transmitted. The longer the delay time is, the slower the transmission speed will be. Inter-Character Delay… (*0~254) 1) Read the barcode above to specify the inter-character delay.
1560 Series Barcode Scanner User Guide 2.6.5 HID CHARACTER TRANSMIT MODE By default, HID interface sends data to the host in batch. You may have the scanner read the “By Character” barcode to process data one character at a time.
Chapter 2 Selecting Output Interface 2.7 USB VIRTUAL COM VIA 3656 Use the USB cable to connect the scanner via 3656 to the USB port of PC and connect the power supply cord. You may run HyperTerminal.exe on your computer, and the scanned data will be transmitted to the computer. Warning: When the 3656 stand is solely on USB power, the current may be insufficient for it to function normally. You must connect the power supply cord.
1560 Series Barcode Scanner User Guide 2.7.3 ACK/NAK TIMEOUT By default, the scanner sends data to the host without waiting for an ACK/NAK response before sending more data. Specify a value, ranging from 1 to 99 in units of 0.1 second. If no response within the specified period of time, the scanner will attempt to send the same data two more times. If all three attempts fail without any notification, data loss will occur.
Chapter 3 SETTING UP A WPAN CONNECTION The 1560/1562 scanner can be configured to send data to a host computer wirelessly via the 3656 stand, or to a notebook computer or PDA with Bluetooth® wireless technology. Upon powering up, the scanner will be ready for establishing a WPAN connection. To establish a connection via 3656 after reading “Set Connection” and “Serial No.” labels … Interface Option Reference Keyboard Wedge 2.4 Keyboard Wedge via 3656 RS-232 2.5 RS-232 via 3656 USB HID 2.
1560 Series Barcode Scanner User Guide 3.1 CONNECTING VIA 3656 By default, the interface of 3656 is set to “USB HID”. Use the interface cable to connect the scanner via 3656 to PC. You can have up to seven scanners connected to one computer at the same time. Note: If you are using USB Virtual COM for the first time, you must install its driver from the CD-ROM. Driver version 5.3 or later is required. Please remove older versions! 3.1.
Chapter 3 Setting up a WPAN Connection 3.1.2 CHANGE INTERFACE If you want to change the interface cable of 3656, use one of the scanners to configure the interface-related settings and it will pass the new settings to 3656, which will then initialize and pass the settings to any other connected scanners. 1) Have the scanner read the “Set Connection” and “Serial Number” labels at the back of 3656. 2) Within two minutes, connect the interface cable between 3656 and your computer.
1560 Series Barcode Scanner User Guide 3.1.3 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enabled, meaning the scanner will listen to the wireless network at a reduced rate.
Chapter 3 Setting up a WPAN Connection 3.2 CONNECTING VIA BLUETOOTH® DONGLE 3.2.1 CHANGE INTERFACE Below is the procedure to configure the scanner before establishing a WPAN connection via Bluetooth® dongle. 1) Have the scanner read the “Enter Setup” barcode to enter the configuration mode.
1560 Series Barcode Scanner User Guide 3.2.2 CONFIGURE RELATED SETTINGS Sniff Mode (Power-saving) By default, this feature is enabled, meaning the scanner will listen to the wireless network at a reduced rate. *Enable Disable Note: When connecting more than two scanners to a notebook computer or PDA with Bluetooth® wireless technology, we suggest that you disable the power-saving setting for a more reliable connection.
Chapter 3 Setting up a WPAN Connection Authentication When any changes are made to authentication and PIN code on the scanner side, you will have to remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. The scanner allows up to 16 characters for a PIN code and provides two options for authentication: Enable Authentication with Preset PIN Have the scanner read the “Use preset PIN” barcode, and change the preset PIN if necessary.
1560 Series Barcode Scanner User Guide Use random PIN No PIN required Note: When using BT HID, some device driver may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to “No PIN or use random PIN” before pairing. While pairing, the host PIN code will be displayed on the computer screen. Have the scanner read the setup barcode “Enter PIN Code in Decimal” or “Enter PIN Code in Hexadecimal” to input the matching PIN code.
Chapter 3 Setting up a WPAN Connection 3.2.3 CONNECT TO DONGLE The procedure goes through associating devices for establishing a WPAN connection, which is pretty much the same except for the software you are using. If your computer is running Microsoft® Windows® XP Service Pack 3 (SP3) or Windows Vista® Service Pack 1 (SP1), you can use the software support that Windows® includes, or you can use the driver that the device manufacturer provides.
1560 Series Barcode Scanner User Guide 4. Turn on the scanner with correct WPAN settings, such as select BT SPP or BT HID, broadcasting enabled, authentication enabled, and PIN code specified, etc. Select the check box of [My device is set up and ready to be found] on your computer. 5. Click [Next]. 6. Wait for a few seconds for the Wizard to search available devices nearby. The scanner will appear with its “serial number” as the device name.
Chapter 3 Setting up a WPAN Connection 7. Click [Next]. 8. Enter the passkey for authentication, which must be exactly the same as configured for the scanner.
1560 Series Barcode Scanner User Guide 9. Click [Next]. Wait for a few seconds for Windows to exchange passkeys.
Chapter 3 Setting up a WPAN Connection Note: When Bluetooth security is enabled without providing a pre-set PIN code, dynamic input of PIN code is supported. 10. Click [Finish].
1560 Series Barcode Scanner User Guide 11. Now the target scanner will be listed as shown below. You can have up to seven scanners connected to one computer at the same time. Select and Remove Note: When any changes are made to authentication and PIN code on the scanner side, or you want to change to use BT HID, it is suggested that you remove the scanner from the paired device list (called unpairing) and go through the whole process to re-establish the connection. 12.
Chapter 3 Setting up a WPAN Connection BT SPP Connected BT SPP Disconnected 115 Update
1560 Series Barcode Scanner User Guide 116 Enter Setup
Chapter 4 CHANGING SYMBOLOGY SETTINGS In this chapter, a brief on the symbology settings is provided for your reference. IN THIS CHAPTER 4.1 Codabar ..................................................................118 4.2 Code 25 – Industrial 25 .............................................120 4.3 Code 25 – Interleaved 25...........................................123 4.4 Code 25 – Matrix 25..................................................126 4.5 Code 39 ...................................................
1560 Series Barcode Scanner User Guide 4.1 CODABAR *Enable Disable 4.1.
Chapter 4 Changing Symbology Settings 4.1.2 START/STOP TRANSMISSION Decide whether to include the start/stop characters in the data being transmitted. Transmit Start/Stop Characters *Do Not Transmit 4.1.3 CLSI CONVERSION When enabled, the CLSI editing strips the start/stop characters and inserts a space after the first, fifth, and tenth characters of a 14-character Codabar barcode. Apply CLSI Editing *Do Not Apply Note: The 14-character barcode length does not include start/stop characters.
1560 Series Barcode Scanner User Guide 4.2 CODE 25 – INDUSTRIAL 25 *Enable Disable 4.2.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25".
Chapter 4 Changing Symbology Settings 4.2.2 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted. Verify Industrial 25 Check Digit *Do Not Verify 4.2.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
1560 Series Barcode Scanner User Guide 4.2.4 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified.
Chapter 4 Changing Symbology Settings 4.3 CODE 25 – INTERLEAVED 25 *Enable Disable 4.3.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25".
1560 Series Barcode Scanner User Guide 4.3.2 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted. Verify Interleaved 25 Check Digit *Do Not Verify 4.3.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
Chapter 4 Changing Symbology Settings 4.3.4 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified.
1560 Series Barcode Scanner User Guide 4.4 CODE 25 – MATRIX 25 Enable *Disable 4.4.1 START/STOP PATTERN SELECTION This decides the readability of all 2 of 5 symbology variants. For example, flight tickets actually use an Industrial 2 of 5 barcode but with Interleaved 2 of 5 start/stop pattern. In order to read this barcode, the start/stop pattern selection parameter of Industrial 2 of 5 should set to "Interleaved 25".
Chapter 4 Changing Symbology Settings 4.4.2 VERIFY CHECK DIGIT Decide whether to verify the check digit. If incorrect, the barcode will not be accepted. Verify Matrix 25 Check Digit *Do Not Verify 4.4.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
1560 Series Barcode Scanner User Guide 4.4.4 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified.
Chapter 4 Changing Symbology Settings 4.5 CODE 39 *Enable Disable 4.5.1 START/STOP TRANSMISSION Decide whether to include the start/stop characters in the data being transmitted. Transmit Code 39 Start/Stop Characters *Do Not Transmit 4.5.2 VERIFY CHECK DIGIT Decide whether to verify check digit. If incorrect, the barcode will not be accepted.
1560 Series Barcode Scanner User Guide 4.5.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted. *Transmit Code 39 Check Digit Do Not Transmit 4.5.4 STANDARD/FULL ASCII CODE 39 Decide whether to support Code 39 Full ASCII that includes all the alphanumeric and special characters.
Chapter 4 Changing Symbology Settings 4.6 CODE 93 *Enable Disable 4.
1560 Series Barcode Scanner User Guide 4.
Chapter 4 Changing Symbology Settings 4.8.1 CONVERT TO EAN-13 Decide whether to expand the read EAN-8 barcode, as well as its addons, into EAN-13. After conversion, the data follows EAN-13 format and is affected by EAN-13 programming selections (e.g. Check Digit). Convert EAN-8 to EAN-13 *Do Not Convert 4.8.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
1560 Series Barcode Scanner User Guide 4.
Chapter 4 Changing Symbology Settings 4.9.1 ISBN CONVERSION Decide whether to convert the EAN-13 barcode, starting with 978 and 979, to ISBN. Convert EAN-13 to ISBN *Do Not Convert 4.9.2 ISSN CONVERSION Decide whether to convert the EAN-13 barcode, starting with 977 to ISSN. Convert EAN-13 to ISSN *Do Not Convert 4.9.3 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
1560 Series Barcode Scanner User Guide 4.9.4 SECURITY LEVEL Select the security level for reading EAN-13 barcodes.
Chapter 4 Changing Symbology Settings 4.10 GS1-128 (EAN-128) Enable *Disable Note: When this setting is disabled, GS1-128 barcodes used to be taken as Code 128. However, starting from firmware version 1.01, GS1-128 barcodes can be decoded only when this setting is enabled. 4.10.1 CODE ID TRANSMISSION Decide whether to include the Code ID ("]C1") in the data being transmitted. Transmit Code ID *Do Not Transmit 4.10.
1560 Series Barcode Scanner User Guide 4.11 ISBT 128 *Enable Disable Note: When enabled, it not only can decode single ISBT barcode, but also decode and concatenates pairs of ISBT barcodes.
Chapter 4 Changing Symbology Settings 4.12 MSI Enable *Disable 4.12.1 VERIFY CHECK DIGIT Select one of the three calculations to verify check digit when decoding barcodes. If incorrect, the barcode will not be accepted. *Single Modulo 10 Double Modulo 10 Modulo 10 & 11 4.12.2 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
1560 Series Barcode Scanner User Guide 4.12.3 CODE LENGTH QUALIFICATION To prevent the "short scan" error, define the "Length Qualification" settings to ensure that the correct barcode is read by qualifying the allowable code length. If "Max/Min Length" is selected, the maximum length and the minimum length must be specified. It only accepts those barcodes with lengths that fall between max/min lengths specified. If “Fixed Length” is selected, up to 2 fixed lengths can be specified.
Chapter 4 Changing Symbology Settings 4.13 FRENCH PHARMACODE Enable *Disable 4.13.1 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
1560 Series Barcode Scanner User Guide 4.14 ITALIAN PHARMACODE Enable *Disable 4.14.1 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
Chapter 4 Changing Symbology Settings 4.15 PLESSEY Enable *Disable 4.15.1 CONVERT TO UK PLESSEY Decide whether to change each occurrence of the character 'A' to character 'X' in the decoded data. Convert to UK Plessey *Do Not Convert 4.15.2 TRANSMIT CHECK DIGIT Decide whether to include the two check digits in the data being transmitted.
0 Series Barcode Scanner User Guide 4.
Chapter 4 Changing Symbology Settings 4.16.2 GS1 DATABAR OMNIDIRECTIONAL (RSS-14) Enable RSS-14 & RSS Expanded (Groups I, II) *Disable The settings below apply to Group I symbologies only: GS1 DataBar Omnidirectional GS1 DataBar Truncated GS1 DataBar Stacked GS1 DataBar Stacked Omnidirectional Transmit Code ID Decide whether to include the Code ID in the data being transmitted.
1560 Series Barcode Scanner User Guide Transmit Check Digit Decide whether to include the check digit in the data being transmitted.
Chapter 4 Changing Symbology Settings 4.16.3 GS1 DATABAR EXPANDED (RSS EXPANDED) Enable RSS-14 & RSS Expanded (Groups I, II) *Disable The settings below apply to Group II symbologies only: GS1 DataBar Expanded GS1 DataBar Expanded Stacked Transmit Code ID Decide whether to include the Code ID in the data being transmitted.
1560 Series Barcode Scanner User Guide 4.16.4 GS1 DATABAR LIMITED (RSS LIMITED) Enable RSS Limited (Group III) *Disable Transmit Code ID Decide whether to include the Code ID in the data being transmitted. *Transmit RSS Limited Code ID Do Not Transmit Transmit Application ID Decide whether to include the Application ID ("01") in the data being transmitted. *Transmit RSS Limited Application ID Do Not Transmit Transmit Check Digit Decide whether to include the check digit in the data being transmitted.
Chapter 4 Changing Symbology Settings 4.17 TELEPEN Enable Telepen *Disable 4.17.1 TELEPEN OUTPUT – FULL ASCII/NUMERIC Decide whether to support Telepen in full ASCII code. By default, it supports ASCII mode. AIM Telepen (Full ASCII) includes all the alphanumeric and special characters.
1560 Series Barcode Scanner User Guide 4.
Chapter 4 Changing Symbology Settings 4.18.1 CONVERT TO EAN-13 Decide whether to expand the read UPC-A barcode, as well as its addons, into EAN-13. After conversion, the data follows EAN-13 format and is affected by EAN-13 programming selections (e.g. Check Digit). Convert UPC-A to EAN-13 *Do Not Convert 4.18.2 SYSTEM NUMBER TRANSMISSION Decide whether to include the system number in the data being transmitted. *Transmit UPC-A System Number Do Not Transmit 4.18.
1560 Series Barcode Scanner User Guide 4.
Chapter 4 Changing Symbology Settings 4.19.1 SYSTEM NUMBER SELECTION Decide whether to decode the ordinary UPC-E barcodes only or both UPC-E0 and UPC-E1 barcodes. System number 0 enabled for decoding UPC-E0 barcodes. System number 1 enabled for decoding UPC-E1 barcodes. System Number 0 & 1 *System Number 0 Only Warning: Because of the way system number 1 is encoded, if both system numbers are enabled, the user might suffer from short scanning UPC-A or EAN-13 barcodes into UPC-E1 barcodes. 4.19.
1560 Series Barcode Scanner User Guide 4.19.3 SYSTEM NUMBER TRANSMISSION Decide whether to include the system number in the data being transmitted. Transmit UPC-E System Number *Do Not Transmit 4.19.4 TRANSMIT CHECK DIGIT Decide whether to include the check digit in the data being transmitted.
Chapter 5 DEFINING OUTPUT FORMAT You may configure in which format the collected data will be output to the host computer. Barcode read by the scanner will be processed in the following sequence – 1) Perform character substitution on the data scanned. 2) Add Code ID and Length Code to the front of the data:[Code ID][Length Code][Data] 3) Process the whole data in step 2 with user formats. Data is now divided into fields by user specified rules. Refer to Chapter 6 Applying Formats for Data Editing.
1560 Series Barcode Scanner User Guide 5.2 CHARACTER SUBSTITUTION Character substitution is performed on every occurrence of the first character specified. If only one character is specified, every occurrence of that character in the barcode will be taken away. The first character will be replaced by the second character(s). Up to three sets of character substitution can be configured.
Chapter 5 Defining Output Format 5.2.1 SELECT A SET FOR CHARACTER SUBSTITUTION Configure Set 1 Configure Set 2 Configure Set 3 1) Read the barcode above to enable character substitution by set. For example, have the scanner read the “Set 1” barcode to configure the first set of character substitution. The scanner will respond with one short beep, high tone, to indicate more setup barcodes are required. 2) Read the “Hexadecimal Value” barcode on page 228 for the desired character substitution.
1560 Series Barcode Scanner User Guide 5.2.2 SYMBOLOGIES FOR CHARACTER SUBSTITUTION (ALL 3 SETS) By default character substitution will be performed on all symbologies. If the character substitution is not desired with one or more symbologies, read the “Do Not Apply” barcode for each undesired symbologies and all the three sets will be ignored for them.
Chapter 5 Defining Output Format Character Substitution for GS1-128 *Apply Do Not Apply Character Substitution for ISBT 128 *Apply Do Not Apply Character Substitution for EAN-8 (No Addon) *Apply Do Not Apply Character Substitution for EAN-8 Addon 2 *Apply Do Not Apply Character Substitution for EAN-8 Addon 5 *Apply Do Not Apply 159 Update
1560 Series Barcode Scanner User Guide Character Substitution for EAN-13 (No Addon) *Apply Do Not Apply Character Substitution for EAN-13 Addon 2 *Apply Do Not Apply Character Substitution for EAN-13 Addon 5 *Apply Do Not Apply Character Substitution for French Pharmacode *Apply Do Not Apply Character Substitution for Italian Pharmacode *Apply Do Not Apply 160 Enter Setup
Chapter 5 Defining Output Format Character Substitution for Industrial 25 *Apply Do Not Apply Character Substitution for Interleaved 25 *Apply Do Not Apply Character Substitution for Matrix 25 *Apply Do Not Apply Character Substitution for MSI *Apply Do Not Apply Character Substitution for Plessey *Apply Do Not Apply 161 Update
1560 Series Barcode Scanner User Guide Character Substitution for GS1 DataBar *Apply Do Not Apply Character Substitution for Telepen *Apply Do Not Apply Character Substitution for UPC-A (No Addon) *Apply Do Not Apply Character Substitution for UPC-A Addon 2 *Apply Do Not Apply Character Substitution for UPC-A Addon 5 *Apply Do Not Apply 162 Enter Setup
Chapter 5 Defining Output Format Character Substitution for UPC-E (No Addon) *Apply Do Not Apply Character Substitution for UPC-E Addon 2 *Apply Do Not Apply Character Substitution for UPC-E Addon 5 *Apply Do Not Apply 163 Update
1560 Series Barcode Scanner User Guide 5.3 PREFIX/SUFFIX CODE By default, there is no prefix code, and [ENTER] or [CR] (Carriage Return) is configured to be suffix code. Up to 8 characters can be configured, for example, “Barcode_”, and you will have the string appear in front of the barcode read, like this – “Barcode_1234567890”. If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable.
Chapter 5 Defining Output Format 5.4 CODE ID Up to two characters for Code ID can be configured for each symbology. To make the Code ID configuration easier, the scanner provides five pre-defined Code ID sets that you can select one and make necessary changes on it. If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type.
1560 Series Barcode Scanner User Guide Code ID options Set 1 Set 2 Set 3 Set 4 Set 5 Code 39 A C Y M A Italian Pharmacode A C Y M A French Pharmacode A C Y M A Industrial 25 C H H H S Interleaved 25 D I Z I S Matrix 25 E G G G S Codabar F N X N F Code 93 I L L L G Code 128 H K K K C ISBT 128 H K K K C UPC-E S E C E E EAN-8 P B B FF E EAN-13 M A A F E UPC-A J A A A E MSI V V D P M Plessey W W E Q P Telepen
Chapter 5 Defining Output Format 5.4.2 CHANGE CODE ID 1) Read the barcode below to change code ID of a specific symbology. 2) Read the “Hexadecimal Value” barcode on page 228 for the desired character string. For example, read “4” and “4” for applying the character [D] for Code ID. 3) Read the “Validate” barcode to complete this setting.
1560 Series Barcode Scanner User Guide Configure Code ID for Interleaved 25 Configure Code ID for Matrix 25 Configure Code ID for MSI Configure Code ID for Plessey Configure Code ID for Telepen Configure Code ID for UPC-A Configure Code ID for UPC-E 5.4.
Chapter 5 Defining Output Format 5.5 LENGTH CODE A two-digit code representing the length of barcode data (character count) can be inserted in front of data being transmitted. Such "Length" code can be individually enabled or disabled for each symbology.
1560 Series Barcode Scanner User Guide Length Code for GS1-128 & GS1 DataBar Apply *Do Not Apply Length Code for ISBT 128 Apply *Do Not Apply Length Code for EAN-8 Apply *Do Not Apply Length Code for EAN-13 Apply *Do Not Apply Length Code for French Pharmacode Apply *Do Not Apply 170 Enter Setup
Chapter 5 Defining Output Format Length Code for Italian Pharmacode Apply *Do Not Apply Length Code for Industrial 25 Apply *Do Not Apply Length Code for Interleaved 25 Apply *Do Not Apply Length Code for Matrix 25 Apply *Do Not Apply Length Code for MSI Apply *Do Not Apply 171 Update
1560 Series Barcode Scanner User Guide Length Code for Plessey Apply *Do Not Apply Length Code for Telepen Apply *Do Not Apply Length Code for UPC-A Apply *Do Not Apply Length Code for UPC-E Apply *Do Not Apply 172 Enter Setup
Chapter 5 Defining Output Format 5.6 MULTI-BARCODE EDITOR The Multi-Barcode Editor allows you to decide the output sequence of a concatenation of barcodes. Up to five barcodes can be specified. When you enable this mode, it will force the scanner to apply Laser mode as the scan mode. Note: The Multi-Barcode Editor has nothing to do with Multi-Barcode Mode. The barcodes that are found meeting the specified criteria below will be arranged in the desired sequence.
1560 Series Barcode Scanner User Guide 5.6.1 EDIT A CONCATENATION OF BARCODES Edit Output Sequence 1) Read the barcode above to start editing a concatenation of barcodes. 2) Code Type setting – read the “Hexadecimal Value” barcode on page 228 for Code Type of the (first) barcode. For example, read “4” and “1” for Code 39.
Chapter 5 Defining Output Format 5.6.2 ACTIVATE THE CONCATENATION OF BARCODES By default, the output sequence editing of the concatenation of barcodes is not applied. When “Enforce Output Sequence” is enabled, all barcodes read by the scanner must meet with the criteria for the concatenation. If data is found excluded from all output sequence sets (= not meeting with the criteria), the scanner will not accept the reading, and therefore, data will not be transmitted.
1560 Series Barcode Scanner User Guide 5.7 REMOVAL OF SPECIAL CHARACTER You can only specify 1 character, but it will remove every matching character encountered from the starting position of barcode data until a different character is met. For example, if it is configured to remove the character “0” (hex value is “30”), one or more zeros will be stripped off the barcode data “012345” and “00012345”. However, for barcode data “010333”, only the first zero will be stripped off.
Chapter 6 APPLYING FORMATS FOR DATA EDITING The scanner allows advanced data editing by applying user-configured editing formats. The whole processed data can be divided into fields by user-specified rules. These fields together with the user-configurable additional fields consist of the data actually sent to the host computer.
1560 Series Barcode Scanner User Guide 6.1 ACTIVATING EDITING FORMATS 6.1.1 ACTIVATE EDITING FORMATS If you have already configured any editing format before, you may directly apply the editing format. If not, you must start with configuring an editing format first, and then, activate the editing format when it is desired in use.
Chapter 6 Applying Formats for Data Editing Editing Format 5 Enable *Disable 6.1.2 EXCLUSIVE DATA EDITING By default, only barcodes found meeting with the criteria are processed by the editing formats. Those found not meeting with the criteria are processed normally. When “Exclusive Data Editing” is enabled, all barcodes read by the scanner must be processed by the editing formats.
1560 Series Barcode Scanner User Guide 6.
Chapter 6 Applying Formats for Data Editing 6.2.1 SELECT FORMAT TO CONFIGURE Start Programming Format Select one editing format (Format 1~5) and the parameters pertaining to the editing format can then be configured – applicable code type, data length, matching string & location, start position, field adjustment, total number of fields, field settings (field-dividing rule), additional fields, and field transmission sequence. Up to five different formats can be specified.
1560 Series Barcode Scanner User Guide 6.2.2 RESTORE DEFAULT FORMAT You may select an existing editing format and have the defaults restored. The default settings of an editing format are listed below.
Chapter 6 Applying Formats for Data Editing 6.3 CONFIGURING FORMAT — DEFINE DATA CRITERIA Three applicable conditions can be configured to check whether the data read by the scanner can be processed by the particular editing format. Note: Data editing cannot be performed unless the three conditions are all met. 6.3.1 APPLICABLE CODE TYPE By default, barcodes of all the supported symbologies will be processed by any editing format, if having been configured and enabled.
1560 Series Barcode Scanner User Guide Editing Format for Codabar *Apply Do Not Apply Editing Format for Code 39 *Apply Do Not Apply Editing Format for Code 93 *Apply Do Not Apply Editing Format for Code 128 *Apply Do Not Apply Editing Format for GS1-128 & GS1 DataBar *Apply Do Not Apply 184 End Programming Format
Chapter 6 Applying Formats for Data Editing Editing Format for ISBT 128 *Apply Do Not Apply Editing Format for EAN-8 *Apply Do Not Apply Editing Format for EAN-8 Addon 2 *Apply Do Not Apply Editing Format for EAN-8 Addon 5 *Apply Do Not Apply Editing Format for EAN-13 *Apply Do Not Apply 185 Update
1560 Series Barcode Scanner User Guide Editing Format for EAN-13 Addon 2 *Apply Do Not Apply Editing Format for EAN-13 Addon 5 *Apply Do Not Apply Editing Format for French Pharmacode *Apply Do Not Apply Editing Format for Italian Pharmacode *Apply Do Not Apply Editing Format for Industrial 25 *Apply Do Not Apply 186 End Programming Format
Chapter 6 Applying Formats for Data Editing Editing Format for Interleaved 25 *Apply Do Not Apply Editing Format for Matrix 25 *Apply Do Not Apply Editing Format for MSI *Apply Do Not Apply Editing Format for Plessey *Apply Do Not Apply Editing Format for Telepen *Apply Do Not Apply 187 Update
1560 Series Barcode Scanner User Guide Editing Format for UPC-A *Apply Do Not Apply Editing Format for UPC-A Addon 2 *Apply Do Not Apply Editing Format for UPC-A Addon 5 *Apply Do Not Apply Editing Format for UPC-E *Apply Do Not Apply Editing Format for UPC-E Addon 2 *Apply Do Not Apply 188 End Programming Format
Chapter 6 Applying Formats for Data Editing Editing Format for UPC-E Addon 5 *Apply Do Not Apply 189 Update
1560 Series Barcode Scanner User Guide 6.3.2 DATA LENGTH The length must include prefix, suffix (0x0d by default), length code, etc. By default, barcodes of any length (character count) are eligible for data editing. You may specify a value from 0 to 254. When zero is given to both, the scanner will not perform the length qualification. 1) Read the barcode below to specify Max. Length or Min. Length separately, and follow steps 2~3. Max. Length Min.
Chapter 6 Applying Formats for Data Editing 6.3.3 MATCHING STRING & LOCATION By default, no matching string is specified, and therefore, it is disabled. You may enable this feature by specifying a matching string; up to four characters are allowed. When the Matching String Location is zero, the scanner will only check for the existence of the matching string in the barcode data. You may specify a value from 1 to 254 to indicate where the matching string starts in the barcode data.
1560 Series Barcode Scanner User Guide 6.4 CONFIGURING FORMAT — DEFINE DATA FIELD 6.4.1 START POSITION Data can be divided into fields in one of the following direction – from head (F1) to tail (F5) from tail (F1) to head (F5) *From Head From Tail 6.4.2 FIELD ADJUSTMENT You may apply equal length to all fields, if necessary. If data is found longer than specified, it will be truncated automatically. When data is found shorter, it will add “Space” (0x20) to field.
Chapter 6 Applying Formats for Data Editing 6.4.3 TOTAL NUMBER OF FIELDS Data can be divided into at most 6 fields; each of them is numbered from F1 to F6 accordingly. However, only F1~F5 can be configured. The total number of fields must be specified correctly. If three fields are configured for the editing format, the data characters after F3 will be assigned to F4 automatically. This feature is quite useful especially when data of variable lengths is processed by editing formats.
1560 Series Barcode Scanner User Guide 6.4.4 FIELD SETTINGS Data eligible for editing formats is divided into fields by user-specified rules – either using the field terminating string or specified field length. By Terminating String Specify the field terminating string. Up to two characters are allowed. The scanner will search for the occurrence of this particular string in the data. By default, this string will be included in the field. You may discard it.
Chapter 6 Applying Formats for Data Editing Field 2 Setting 1. Read the barcode below to divide field 2 by a specified terminating string. Select Field Separator to Divide Field 2… 2. Read the “Hexadecimal Value” barcode on page 228 for the desired character string. 3. Read the “Validate” barcode to complete this setting. 4. Read the “Discard Separator” barcode if the field separator is not desired in the field.
1560 Series Barcode Scanner User Guide Field 3 Setting 1. Read the barcode below to divide field 3 by a specified terminating string. Select Field Separator to Divide Field 3… 2. Read the “Hexadecimal Value” barcode on page 228 for the desired character string. 3. Read the “Validate” barcode to complete this setting. 4. Read the “Discard Separator” barcode if the field separator is not desired in the field.
Chapter 6 Applying Formats for Data Editing Field 4 Setting 1. Read the barcode below to divide field 4 by a specified terminating string. Select Field Separator to Divide Field 4… 2. Read the “Hexadecimal Value” barcode on page 228 for the desired character string. 3. Read the “Validate” barcode to complete this setting. 4. Read the “Discard Separator” barcode if the field separator is not desired in the field.
1560 Series Barcode Scanner User Guide Field 5 Setting 1. Read the barcode below to divide field 5 by a specified terminating string. Select Field Separator to Divide Field 5… 2. Read the “Hexadecimal Value” barcode on page 228 for the desired character string. 3. Read the “Validate” barcode to complete this setting. 4. Read the “Discard Separator” barcode if the field separator is not desired in the field.
Chapter 6 Applying Formats for Data Editing Additional Fields Up to five additional fields can be created for each editing format; each of them is numbered from AF1 to AF5 accordingly. If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. You may decide whether or not to apply Key Status when “Normal Key” is selected for Key Type. Key Type Key Status Scan Code Up to 2 scan code values are allowed.
1560 Series Barcode Scanner User Guide 6.4.5 PAUSE FIELD SETTING Pause Field Time You can limit the pause time interval (1~16). By default, it is set to 1 second. Pause Field Time 1~16 sec. (*1) 1. Read the barcode above to specify the time interval for the Pause Field. (It is set to 1 by default.) 2. Read the “Decimal Value” barcode on page 227. For example, read “1” and “0” for setting the Pause Field Time to 10 seconds. 3. Read the “Validate” barcode on the same page to complete this setting.
Chapter 6 Applying Formats for Data Editing 6.5 CONFIGURING FORMAT — DEFINE TRANSMISSION SEQUENCE After configuring the data fields and additional fields, you must now program the transmission sequence of these fields that comprise the final data. This field transmission sequence can be assigned in any desired order and fields can be assigned multiple times as well. Note: Up to twelve fields can be assigned. 1) Read the “Start” barcode to begin with programming the field transmission sequence.
1560 Series Barcode Scanner User Guide Additional Field 2 Additional Field 3 Additional Field 4 Additional Field 5 Pause Field Null Character Field 3) Read the “End” barcode to complete this setting.
Chapter 6 Applying Formats for Data Editing 6.6 PROGRAMMING EXAMPLES 6.6.1 EXAMPLE I Extract data from the 10th character to the 19th character... The editing format should be configured as follows: 1. Read the “Enter Setup” barcode to enter the Configuration Mode. 2. Read the “Configure Format 1” barcode. 3. Read the “Clear All” and “Code 128” barcodes for applicable code type. 4. Read the “Three Fields” barcode. 5. Read the “Divide Field 1 by Length” barcode, and set length to 9.
1560 Series Barcode Scanner User Guide 6.6.2 EXAMPLE II Extract the date code, item number, and quantity information from barcodes. Data in a barcode is encoded like this: From the 1st character to the 6th character is the date code. From the 7th character to the dash ‘-’ character is the item number. After the dash ‘-’ character is the quantity information.
SPECIFICATIONS Optical Characteristics 1560 1562 Scan Engine Non-contact type Non-contact type Optical Sensor CCD, 2500 pixels Laser Light Source Visible red LED Visible laser diode RF Characteristics WPAN Module Wireless PAN BT Class 2 compliance Coverage (line-of-sight) 90 meters with 3656 Interface Supported Serial Port Profile (BT SPP) 4 KB for transmit buffer Human Interface Device Profile (BT HID) 3656 Physical Characteristics Memory 512 KB flash for memory mode Swit
1560 Series Barcode Scanner User Guide Electrical Characteristics Battery Rechargeable Li-ion battery – 3.7 V, 800 mAh Power Adaptor Input AC 100~240 V, 50/60 Hz Output DC 5V, 2A (3656) DC 5V 0.5A (Battery Charger) Operating Temperature 0 °C to 40 °C Environmental Characteristics Temperature Humidity (Non-condensing) Operating 0 °C to 50 °C Storage -20 °C to 60 °C Operating 10% to 90% Storage 5% to 95% Resistance Impact Resistance 1.
Appendix I FIRMWARE UPGRADE You can only upgrade firmware of one scanner at a time. For example, you must turn off each of the rest 1560/1562 scanners when there is more than one scanner connected to your computer. Note: In case it fails downloading due to low battery, make sure the targe scanner is loaded with good battery and the battery charge is enough. HOW TO UPGRADE 1560/1562 FIRMWARE USING 3656 1) Connect the interface cable, RS-232 or USB, between 3656 and your computer.
1560 Series Barcode Scanner User Guide Enter Setup Activate 3656 USB Virtual COM Update 5) Read the following barcodes in sequence for the scanner to enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading. Enter Setup Download 6) Run the download utility “ProgLoad.exe” on your computer. Kernel Program User Program K1560_V*.shx STD1560_V*.
Appendix I Firmware Upgrade 7) After upgrading kernel, you will need to manually restart the scanner. After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully. Note: The output interface remains unchanged as specified in step 3 (= RS-232 or USB Virtual COM).
1560 Series Barcode Scanner User Guide USING BLUETOOTH® DONGLE 1) Refer to 3.2.3 Connect to Dongle for the target scanner to accept the connection request from your computer. 2) Read the following barcodes in sequence to configure the scanner to use BT SPP as download interface. Enter Setup Activate BT SPP Update 3) Read the following barcodes in sequence for the scanner to enter the download mode. The scanner will respond with beeps to indicate it is ready for downloading.
Appendix I Firmware Upgrade For the communication settings, select “RS-232” and the correct COM port for BT SPP interface. Ignore the baud rate setting. Click [OK]. For the file option, click [Browse] to select the target file for firmware update. 5) After upgrading kernel, you will need to manually restart the scanner. After upgrading the user program, the scanner will automatically restart itself once the download is completed successfully.
1560 Series Barcode Scanner User Guide HOW TO UPGRADE 3656 FIRMWARE UPGRADING 3656 CPU FIRMWARE 1) Connect the interface cable, RS-232 or USB, between 3656 and your computer. For USB Virtual COM, you may need to install its driver first! 2) Connect the power supply cord from 3656 to a proper power outlet. 3) Refer to 3.1.1 Connect to 3656 for the target scanner to connect to 3656. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656.
Appendix I Firmware Upgrade Enter Setup Download 3656 CPU Firmware 6) Run the download utility “ProgLoad.exe” on your computer. Kernel Program User Program K3656_V*.shx STD3656_V*.shx For the communication settings, select “RS-232” and the correct COM port for RS-232 or USB Virtual COM interface. For RS-232, select 115200 bps for baud rate; for USB Virtual COM, ignore the baud rate setting. For the file option, click [Browse] to select the target file for firmware update. Click [OK].
1560 Series Barcode Scanner User Guide UPGRADING 3656 USB BRIDGE FIRMWARE 1) Connect the USB cable between 3656 and your computer. For USB Virtual COM, you may need to install its driver first! 2) Connect the power supply cord from 3656 to a proper power outlet. 3) Refer to 3.1.1 Connect to 3656 for the target scanner to connect to 3656. Read the “Set Connection” label first, and then the “Serial Number” label. Both labels can be located at the back of 3656.
Appendix I Firmware Upgrade For the communication settings, select “RS-232” and the correct COM port for USB Virtual COM interface. Ignore the baud rate setting. Click [OK]. For the file option, click [Browse] to select the target file for firmware update. 7) The 3656 will automatically restart itself when upgrading firmware is completed successfully. 8) Read the “Update” barcode for the scanner to resume its operation (exit the configuration mode).
1560 Series Barcode Scanner User Guide 216 Enter Setup
Appendix II HOST SERIAL COMMANDS 1560/1562 SERIAL COMMANDS D Purpose To disable the scanner. Remarks “D” E Purpose To enable the scanner. Remarks “E” #@ nnnnnn Purpose To configure the scanner. Remarks nnnnnn – the six digits of command parameters. For example, “109952” is to list the current Code ID settings.
1560 Series Barcode Scanner User Guide #@TRIGOFF Purpose To disable the software trigger Remarks “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x46” + “0x46” + “0x0d” #@TRIGON Purpose To enable the software trigger Remarks “0x23” + “0x40” + “0x54” + “0x52” + “0x49” + “0x47” + “0x4f” + “0x4e” + “0x0d” EXAMPLE You may run HyperTerminal.exe on the host computer to send serial commands to the 1560/1562 scanner via RS-232, USB Virtual COM or BT SPP.
Appendix II Host Serial Commands 3656 SETUP BARCODES & SERIAL COMMANDS Normally, you can configure the 3656 stand by having a connected scanner read 3656-related setup barcodes. 1) Connect the interface cable, RS-232, Keyboard Wedge or USB, between 3656 and your computer. For USB Virtual COM, you may need to install its driver first! 2) Connect the power supply cord from 3656 to a proper power outlet. 3) Refer to 3.1.1 Connect to 3656 for the target scanner to connect to 3656.
1560 Series Barcode Scanner User Guide 3656 SERIAL COMMAND TABLE Config Purpose To configure 3656. Here is the setup barcode for this serial command: Config Remarks A list of the current settings will be displayed. Run HyperTerminal.exe on your computer and change the settings one by one. DefaultSetting Purpose To restore the default settings. Here is the setup barcode for this serial command: DefaultSetting SingleConnection Purpose To allow only one scanner connecting to 3656.
Appendix II Host Serial Commands UseVariablePort Purpose To use variable Virtual COM port when connecting more than one 3656 to PC via USB. Here is the setup barcode for this serial command: UseVariablePort Version Purpose To get the firmware versions (CPU+USB Bridge). Here is the setup barcode for this serial command: Version GetID Purpose To get MAC ID. Here is the setup barcode for this serial command: GetID Download Purpose To download CPU firmware to 3656 via RS-232 or USB.
1560 Series Barcode Scanner User Guide EXAMPLE Without using the scanner to read the above setup barcodes for configuring the 3656 stand, you may run HyperTerminal.exe on the host computer to send serial commands to 3656 via RS-232 or USB. 1) Connect the interface cable, RS-232 or USB, between 3656 and your computer. For USB Virtual COM, you may need to install its driver first! 2) Connect the power supply cord from 3656 to a proper power outlet.
Appendix III KEYBOARD WEDGE TABLE 0 0 1 2 3 4 5 6 7 F2 SP 0 @ P ` p 1 INS F3 ! 1 A Q a q 2 DLT F4 " 2 B R b r 3 Home F5 # 3 C S c s 4 End F6 $ 4 D T d t 5 Up F7 % 5 E U e u 6 Down F8 & 6 F V f v 7 Left F9 ' 7 G W g w 8 BS F10 ( 8 H X h x 9 HT F11 ) 9 I Y i y A LF F12 * : J Z j z B Right ESC + ; K [ k { C PgUp Exec , < L \ l | D CR CR* - = M ] m } E PgDn .
1560 Series Barcode Scanner User Guide KEY TYPE & STATUS KEY TYPE If “BT HID”, “USB HID” or “Keyboard Wedge” is configured for interface, Key Type and Key Status will then become applicable. *Normal Scan Code KEY STATUS Decide whether or not to change key status when “Normal Key” is selected for Key Type.
Appendix III Keyboard Wedge Table EXAMPLE KEY TYPE = NORMAL For example, if you want to program the character “!” as the prefix code: 1. Read the “Configure Prefix” barcode. 2. Read the “Hexadecimal Value” barcode on page 228 for “2” and “1”. 3. Read the “Validate” barcode to complete this setting. KEY TYPE = SCAN CODE For example, if you want to program the character “a” (= “1C” on the scan code table) as the prefix code: 1. Read the “Configure Prefix” barcode. 2. Read the “Scan Code” barcode.
1560 Series Barcode Scanner User Guide 226 Enter Setup
Appendix IV NUMERAL SYSTEMS DECIMAL SYSTEM Decimal 0 1 2 3 4 5 6 7 8 9 Validate the Values Validate Update Abort 227
1560 Series Barcode Scanner User Guide HEXADECIMAL SYSTEM Hexadecimal 0 1 2 3 4 5 6 7 8 9 A B C D E F 228 Enter Setup
Appendix IV Numeral Systems Validate the Values Validate ASCII TABLE 0 0 1 2 3 4 5 6 7 DLE SP 0 @ P ` p 1 SOH DC1 ! 1 A Q a q 2 STX DC2 " 2 B R b r 3 ETX DC3 # 3 C S c s 4 EOT DC4 $ 4 D T d t 5 ENQ NAK % 5 E U e u 6 ACK SYN & 6 F V f v 7 BEL ETB ' 7 G W g w 8 BS CAN ( 8 H X h x 9 HT EM ) 9 I Y i y A LF SUB * : J Z j z B VT ESC + ; K [ k { C FF FS , < L \ l | D CR GS - = M ] m
1560 Series Barcode Scanner User Guide ENTERING PIN CODE FOR AUTHENTICATION USE PRESET PIN 1) In the configuration mode, read the barcode below to use a preset PIN for authentication. Use Preset PIN 2) Read one of the barcodes to specify the PIN code, in decimal or hexadecimal. By default, the PIN code is set to “0000”. Maximum 16 characters are allowed.
Appendix IV Numeral Systems DISABLE AUTHENTICATION OR USE RANDOM PIN In the configuration mode, read the barcode below to disable authentication (= No PIN) or use a random PIN for authentication. *No PIN or use random PIN Note: When using BT HID, some device driver may not support pre-defined PIN code for authentication. In this case, make sure you have the scanner set to “No PIN or use random PIN” before pairing. While pairing, the host PIN code will be displayed on the computer screen.