TROUBLE PROBABLE CAUSE CORRECTIVE ACTION
CELL TO BATTERY CAN
LEAKAGE TO GROUND
DETECTED BY TESTING
Excessive spewage
Damaged cell case to cover seal.
CLEAN BATTERY, CHARGE AND
ADJUST ELECTROLYTE LEVEL.
RECHECK FOR ELECTRICAL
LEAKAGE.
DISCHARGE BATTERY AND
DISASSEMBLE, REPLACE DEFECTIVE
CELL, RECONDITION BATTERY.
FOAMING OF
ELECTROLYTE DURING
CHARGE
Contaminant in electrolyte
DISCHARGE BATTERY AND REPLACE
DEFECTIVE CELL.
RECONDITION BATTERY. REPLACE
CELL THAT CONTINUES TO FOAM
FALSE OR NO BATTERY
HIGH TEMPERATURE
INDICATION
Dirty connections
Loose connections
Improper mating of parts
Shorted thermistor or receptacle due
to KOH intrusion
CLEAN PARTS
INSPECT AND RETIGHTEN
RECEPTACLE
REPLACE SENSOR ASSEMBLY