Specifications

MARATHONNORCO AEROSPACE, INC.
NICKEL-CADMIUM AIRCRAFT BATTERIES
24-34-00
Page 601
JUL 11/14
6.0 ELECTROLYTE LEVEL ADJUSTMENT
During the last 15 minutes of the topping charge, and while the current is still flowing, the cells are at their
most uniform electrolyte level, and it is at this time that the electrolyte level can be most accurately
adjusted.
The electrolyte level should be adjusted using the syringe and appropriate nozzle (available in kit P/N
32480-001).
Electrolyte level adjustments must be made with distilled, deionized or demineralized water only
FIGURE 5
SYRINGE AND NOZZLE ASSEMBLY
SYRINGE & NOZZLE ASSEMBLY
APPLICATION
TABLE 5
ITEM #1
SYRINGE
P/N
ITEM #2
NOZZLE P/N
NOZZLE
LENGTH
(L1)
NOZZLE
COLOR
CELL TYPE
32415-001
32479-001
32479-002
32479-003
32479-004
7/8” (22mm)
1-1/16” (27 mm)
5/8” (16 mm)
2” (51 mm)
Green
White
Blue
Black
12H120, 12M220, 14M220, 15M220,
15SP100, 18H120, 20H120, 24M220,
24H120, 24H100, 24SP100, 25SP100,
28SP100, 36H120, 38H100, 38SP100,
40SP100, 44SP100,
40SP100L, 44SP100L, 52H120C
3H120, 5H120, 17SP100, 17H100,
46SPE100, 20SPE100
10H120, 65H132
24ME220
Battery cells with aerobatic vents require special electrolyte adjustment procedures. Contact
MarathonNorco for further information.
L1