marathon 550 SL, 800 SL, 1100 SL Installation and Operating Instructions 10514V000-462001-0-OCE-Rev.
GB • Only install the drive mechanism to correctly aligned and weightbalanced doors. An incorrectly aligned door could cause serious injury or damage to the drive mechanism. Contents Foreword Symbols Safety Instructions Normal Use Technical Data EU Manufacturers' Declaration Rating Plate Installation marathon SL Control Unit Radio Receiver 868.
GB Safety Instructions for Authorised Radio-controlled Operation Technical Data marathon • The operator of this radio-controlled equipment is in no way protected from interference from other telecommunications systems and facilities (e.g. other radio-controlled equipment that is licensed to operate at the same frequency range).
GB Door Types and Special Accessories* Installation 1 * Accessories are not included in the delivery specification. Supplied Parts and Components Door type C-rails, chain with bogie unit and drive shaft Control unit in housing, push-button cable, mains cable Connecting element Lintel fitting Ceiling mounting Installation accessories in bag comprising: 1 push-button 5 hexagon-head, self-tapping screws 6.5 x 19 4 wood screws 8 x 60 4 plugs S10 4 plain washers 8.
GB • Insert plug (1). Fit two screws (2) with plain washers (3). Tighten screws securely. Pre-assembling the Drive Mechanism • Remove the drive mechanism from its packaging. • Align C-rail (4) at correct height. If necessary, move screws (5). Tighten screws (5). Dispose of the packaging correctly in accordance with local requirements. 8 • Slot two C-rails (1) into connecting element (2) and push together as far as they will go. 9 • Remove nut (1), spring (2) and plain washer (3).
GB Electrical Connections - The supplied power cable must not be shortened or extended. - The voltage of the power source must correspond to that indicated on the drive mechanism's rating plate. - All apparatus that is externally connected must have contacts with safety separation from the mains supply in accordance with IEC364-4-41, Sub-clause 411.1.3.1 - Live parts on the drive mechanism (energised parts e.g.
GB 29.6 marathon SL Control Unit 29.1 If pressed at same time as push-button 1 (29.7), deletes saved force values. 24-pin Socket Unit See DIL switches 7 + 8 for further functions. Maximum cable cross-section: 1.5 mm². Various accessories may be connected to the socket unit. 29.7 Terminal Designation 1 Connection of external aerial only at 40 MHz. 2+3 Push-button 1: supplied with connected interior push-button 4+5 Push-button 2: supplied as vacant 6+7 Safety connection 1 for e.g.
GB 29.9 LED 4 (Start) 29.17 Indicates whether an OPEN or CLOSE command has been given via a push-button or radio. 29.10 Jumper Should the drive mechanism need to be operated without a 'soft run' function or if no TorMinal is available, the 'soft run' function can be deactivated by disconnecting the jumper. Important to note! The 'soft run' function can no longer be activated via the TorMinal once the jumper has been disconnected.
GB Deleting a Manual Remote Control Button from the Radio Receiver Radio Receiver 868.8 MHz If a user of a multi-user garage facility moves house and wants to take his manual remote control with him, then all the codes of the given user's manual remote control have to be deleted from the radio receiver. General Information SOMMER's new radio control system works at a frequency of 868.8 MHz, so that code transfer occurs from the manual remote control to the radio receiver.
GB Checking Force Setting Initial Operation When the force is correctly set, movement of the door in both directions can be stopped by exerting slight hand pressure. Safety Instructions For each movement of the door, the control unit checks the force values it has memorised against those required and automatically adjusts the values accordingly. Very important to note! The force setting is relevant to the system's safety and must therefore be carried out with due care and attention.
GB For your own safety, select as low a force tolerance as possible to ensure that obstacles are identified in a fast, safe manner. Additional Functions • Repeat test runs until the door reaches the UP and DOWN final travel positions. Early Warning Period (DIL switch 5) When the push-button is pressed or the manual remote control is operated, the warning light flashes for 3 seconds before the drive mechanism starts up.
GB Defined Opening and Closing (DIL switch 7) Push-button/radio channel 1 opens and push-button/radio channel 2 closes the door. 2-channel operation can also be used either via the relevant push-buttons or via the manual remote control. Settings: - DIL switch 7 ON - DIL switch 8 OFF - a 2nd push-button on the manual remote control has to be read on to radio channel 2. Relay Output (Terminals 23 + 24) Each time the drive mechanism starts up, a pulse is sent to the relay outlet.
GB Automatic cut-off of supply Obstacle Identification Operation and Handling If, when opening the door, an obstacle is encountered or the light barrier is interrupted, the drive mechanism recognises this and reacts in accordance with the given DIL switch 1 setting. See 29.8. Safety Instructions • The drive mechanism may only be operated if a risk-free force tolerance has been set. The force set should be so small that the closing force does not constitute an injury risk. (See 'Force Setting' section).
GB Impulse Generators Accessories Key switch Opening and closing the door from outside. As the button can only be activated with a key, the opening and closing of the door by unauthorised personnel is eliminated. A connecting wire from the control housing to the key switch must be laid. The accessories listed can be used in conjunction with all SOMMER garage door drive mechanisms.
GB Replacing Filament lamp on Control Unit Maintenance and Care • Disconnect plug from socket. Important Information 37 • Remove light window (2). • Turn lamp (2) anticlockwise and pull off. • Always disconnect the mains plug prior to working on the drive mechanism. • Fit new filament lamp (24 volt, 21 watt, type BA 15s) and turn clockwise until it locks into position. • Keep your hands clear of a moving door and any moving parts. • Closing edges and workings of the door pose risk of injury.
GB Disassembly Warranty and After-sales Service Observe safety instructions! Warranty complies with statutory requirements. Any warranty matters should be discussed with your local stockist. Warranty entitlements only apply for the country in which the drive mechanism was purchased. The sequence of operations is identical to that described in the Section entitled „Installation“ but in reverse order. The setting procedures described are not applicable.