User guide
52
ENGLISH
12. Meter Mode
The Meter Mode lets you select the type of level meters.
• At Normal, all the level meters are displayed.
• At Peak Only, the level meter(s) displays only a peak
level.
1. From stop, push the MENU/STORE EDIT button.
2. Push the or button to select Preset 1, 2 or 3.
3. Push the ENTER button to accept the selected Preset.
4. Push the or button so Meter Mode is
displayed.
5. Push the ENTER button while Meter Mode is
displayed.
The Meter Mode choice (Normal or Peak only) is
flashing.
6. Push the or button to tab through the Meter
Mode choices.
7. When correct, push the ENTER button.
Display returns to Meter Mode.
8. Push the or button to select other Menu
choices for editing. When editing the Preset is
complete, push the MENU/STORE EDIT button to
store the changes, or push the STOP/CANCEL button
to exit Menu mode without making any changes.
9. Display returns to stop mode.
Note:
When Peak Only is set, the battery life will be
extended.
13. Mic Atten.
The Mic Atten. let you select the direct use of microphones
that differ in sensitivity.
• At 0dB there is no microphone attenuation.
• At -20dB, Input from a microphone(s) connected to the
XLR MIC IN jacks is cut by -20dB.
1. From stop, push the MENU/STORE EDIT button.
2. Push the or button to select Preset 1, 2 or 3.
3. Push the ENTER button to accept the selected Preset.
4. Push the or button so Mic Atten is displayed.
5. Push the ENTER button while Mic Atten is displayed.
The Mic Atten choice (0dB or -20dB) is flashing.
6. Push the or button to tab through the Mic
Atten choices.
7. When correct push the ENTER button.
Display returns to Mic Atten.
8. Push the or button to select other Menu
choices for editing. When editing the Preset is
complete, push the MENU/STORE EDIT button to
store the changes, or push the STOP/CANCEL button
to exit Menu mode without making any changes.