Owner`s manual
18
15
8-15. CONTROL PANEL
On the control panel (See Fig. 34) you will find circular LED
display with 8 numbered icons which shows useful status
information regarding the operator and its function and 3
buttons labeled “+”, “-” and “P” which allows you to set all
the adjustments of your operator.
For proper initial operation of the operator, three basic
functions must be set using express programming:
Open Door Position
Close Door Position
Transmitter Coding
Press and hold the “P” button for approximately 2 seconds.
When LED’s 8, 1 and 2 illuminate, release the button. You
are now ready to set or change the desired adjustment. If
no buttons are pressed within 120 seconds while in
programming mode, the control unit reverts back to
operating mode.
TO MAKE OR CHANGE ANY ADJUSTMENT:
HANDY NOTE: If no changes are needed at any particular stage,
you can keep the current information and “skip” over a specific
adjustment by pressing the “P” button once. This is useful to
know if you want to change only one setting, without changing
any of the other adjustments. Simply enter the adjustment mode
by pressing and holding the “P” button for approximately 2
seconds, then press and release “P” repeatedly until your
particular adjustment is reached. This bypasses the unneeded
adjustments, and takes you right to the adjustment you want.
When your adjustment or setting is complete, simply press ”P” as
many times as needed to bypass the remaining steps and exit out
of the program, returning the operator to normal mode.
Y
our new operator has automatic force learning and maximum
force setting. It may be required to change force settings. If the
force needs to be increased or decreased, it should be changed
by one (1) increment at a time. The force should be set as low as
possible, just enough to allow your unobstructed door to travel
freely without reversing or stopping.
N
OTE: You may exit the System Set Up at any time by pressing
the button “P” for more then 5 sec. The set up programming
can be terminated at any time and from any stage. To do so,
press the “P” button for longer than 5 seconds. When
programming is terminated, all LED’s light up once and then
turn off, one after the other.
8-16. INITIAL SYSTEM SET UP
8-17. ADVANCED SETTINGS (cont’d)
Level 1: Functions overview
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 8: RESET
No Yes – – – – – – – – – – – – – –
Level 1
NOTE: Menus 1, 2 and 7 are disabled. Press “+” or “-” button to scroll or
navigate through menus.
Menu 3: Intermediate position OPEN
Set using the (+ / OPEN) and (- / CLOSE) buttons
Menu 4: Intermediate position CLOSE
not available
Menu 5: Soft run position OPEN
Set using the (+ / OPEN) and (- / CLOSE) buttons
Menu 6: Soft run position CLOSE
Set using the (+ / OPEN) and (- / CLOSE) buttons
Fig. 34
P
1
2
1
5
3
7
2
4
6
8
Fig. 35
1
2
Icons Description and LED’s Assignment
LED #1 Photo Eye Sensors
Connectivity/Alignment Indicator
LED #2 “OPEN Door Position”
LED #3 “Intermediate, OPEN Door Position”
LED #4 “CLOSED Door Position”
LED #5 “Reference Point”
LED #6 -----
LED #7 “Impulse (Remote Control)”
LED #8 “Power”
+
2
4
7
Level Menu Factory default setting
Level 1 – Basic function
system reset
Menu 3: Intermediate position OPEN
–
Level 2 – Opener settings
Setting 8
Setting 8
Menu 3: “OPEN” position – operating sensitivity Setting 15
Menu 4: “CLOSE” position – operating sensitivity Setting 15
General overview of the programmable functions
Level 5
Menu 4: Light timer Setting 16
Menu 4: Not available
Menu 5: Soft run position OPEN
–
Menu 6: Soft run position CLOSE
–
Menu 8: RESET
–
After a system reset, all parameters are restored to the
factory settings.
• All the required function in the initial set up and advanced
settings must be re-programmed if it is required.
• The operator must be activated for two (2) complete
uninterrupted cycles in order for all restored or
operating parameters settings to be learned by the
operator again.
Level 4 – Transmitter code
programming
Menu 1: Not available
Menu 2: Intermediate position
–
–
–
In order to guarantee a trouble-free programming:
• The door must be in the “CLOSED” position and engaged
to the drive system (rail) before programming the
operator or a system reset is performed.
IMPORTANT: Align the photo eye sensors before
starting the initial system set up as
outlined in section 8-19, page 21.
Menu 1: “OPEN” position – operating (System) force
Menu 2:
“CLOSE” position – operating (System) force