Owner`s manual
20
13
8-12. INSTALL WALL CONTROL PANEL
8-17. ADVANCED SETTINGS (cont’d)
Legend:
LED off
LED on
LED flashes slowly
LED pulses
LED flashes quickly
Factory default setting
Not possible
–
Level 5 - Special Function
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Menu 4: Operator Light “ON” Timer (in seconds)
5 10 15 20 25 30 35 40 50 80 100 120 150 180 2552
Level 5: Functions overview
8-13. CONNECTING THE SAFETY SENSORS AND WALL CONTROL TO OPERATOR
Fig. 28B
Receiver
Transmitter
Transmitter
Receiver
DUAL DOOR INSTALLATION Fig. 28B
In dual door installations, the transmitter (TX) and the r
eceiver (RX)
photo eye sensors (as marked on each of the photo eye
components) should be mounted as indicate in Fig. 28B. TX and
RX marks located on the back side of the transmitter and receiver.
Fig. 30
24V
Common
(Ground)
Relay
T
R
Wall Control
Photo Eye Sensor System
Not Available
Class 2
Supply 24 Volts
1 2 3 4 5 6 7 8 9 10
Fig. 31
To Terminal 1
To Terminal 2
To Terminal 4
To Terminal 3
The control panel must be mounted inside the garage within sight
of the garage door, clear of all moving garage door parts or any
associated parts - and at least 5 feet above the floor to prevent the
use of these controls by children. The device should only be used
when the door is in clear sight of the user and the door area is free
of people or any obstructions.
Attach 2-conductor wire to the screw terminal on back of
control panel. See Fig. 29 (Back). White wire attaches to
terminal #3 screw, white wire with color stripes attaches to
terminal #4 screw.
Position wall control panel onto wall in desired location.
Mark hole location on wall.
Drill 1/16” pilot holes into wall.
Insert and tighten screws to secure control panel to wall.
Make sure wiring is routed out from behind control through
one of the cutouts to avoid pinching the wires.
If mounting to drywall instead of wood, drill 3/16” pilot holes and
use anchors provided. If mounting to electrical box that is prewired
for this purpose, mount directly to box with proper screws provided.
See Fig. 29A.
Fig. 29
Screw caps
4
3
To Terminal #4 Screw
To Terminal #3 Screw
Fig. 29B
Fig. 29A
Run wires from the wall control panel along the wall and ceiling
to the operator quick-connect terminals, locate on the rear.
Use the staples to secure wiring to wall, joists and ceiling. Do
not pinch wiring. Drive staples with only enough force to hold
wiring in place. Refer to Fig. 6 on p.6 for an example of typical
wiring routing, and Fig. 30 for terminal assignment.
Insert white single wire from wall control into quick-connect
terminal #3 and single color striped wire into quick-connect
terminal #4. See Fig. 31.
NOTE: Individual wall control stations can be combined into one
solid panel.
Detach right side panel from one of the wall controls. (Fig. 29B)
Attach wiring to each wall control.
Combine single panels into one block.
Follow the same steps as above to mount additional wall control
panels and wire connections, only connect one wall control
per operator.
For photo eye system wiring routing refrence section 8-11 on
page 12, Fig. 25A.
Insert the stripped end of the white wir
e combination
firmly into quick-connect terminal #1 by pushing the
wires directly in the terminal hole, see Fig. 32A. If the wires
are difficult to insert, a screwdriver may be used to depress
the terminal "tab" while inserting the wires. To remove wires,
depress the tab again and pull wires out.
Repeat pr
ocedure for the stripe wires (white/black stripe),
insert them into quick-connect terminal #2.
NOTE:
If wires are difficult to insert, a screwdriver may be used to
depress the quick-connect terminal “tab” while inserting the wires.