Specifications
M-Series Water Purification Machines
1238160 Rev. D 2 - 4 Installation Guidelines and Instructions
2.3 Electrical
M-Series models require two supply voltages, the control circuit voltage and a
separate motor voltage. All field wiring must comply with applicable local and
national electrical codes.
All M4 models are supplied with a single-phase, 115 VAC 60 Hz or 230 VAC 50
Hz control circuit with an 8-foot cord with plugs into a three-prong grounded
receptacle. A 20 amp dedicated service circuit is required for proper operation
(see wiring schematic).
The 2200 through 8800 models use a 1.5 Hp, 208-230/460 VAC, three-phase
motor. M-Series 11000 and 13200 models use a 2 Hp, 208-230/460 VAC, three-
phase motor. The motor is wired at the factory to an overload protection
magnetic motor starter. There is also a single-phase motor available on the 2200
and 4400 models only. These models use a 3Hp, 208-230VAC, 60 Hz, single-
phase motor.
A 50Hz option for all M-series models is available. The 2200 through 8800 uses
a 3 Hp 190/380 VAC, three-phase motor. The 11000 and 13200 use a 5 Hp
190/380, three phase motor. A single-phase option is also available for 50Hz
models 2200 and 4400. These models use a 1-1/2 Hp, 220VAC, 50Hz, single-
phase motor.
1. Connect the control circuit power cord to 115 VAC, 60 Hz, or 230 VAC 50
Hz single-phase power.
2. Connect the magnetic motor starter to 208-230/460 VAC or 190-220/380
VAC, three-phase or 115/230 VAC single-phase power to match the motor
voltage and phase. Check the tag (located on the motor starter) that
indicates the factory wiring. A separate, fused disconnect for the wiring with
proper protection for the Hp and the amp draw of the motor is
recommended.
WARNING:
Before obtaining access to terminals, all supply circuits must be
disconnected.