Specifications
  23G-Series RO System 
3024270 Rev G  42  14Oct13 
Table 4.6 ECM-100 Timer Settings 
Timers (Menu 03) 
Range 
Factory Preset 
RO PUMP DELAY 
1 - 99 sec
1
6 seconds 
START-UP PERM DIVERT 
0 - 99 min 
2 minutes 
AUF PERIOD  
0 - 99 hr 
1 hour 
AUF DURATION 
0 - 99 min 
6 minutes 
ALARM SHUTDOWN DELAY 
0 - 99 sec 
15 seconds 
LOG PERIOD  
0 - 99 hr 
1 hour 
AUTO-ON PERIOD 
0 - 99 hr 
(see note 2) 
AUTO-ON DURATION 
0 - 99 min 
(see note 3) 
1.  An RO pump delay of 0 will disable the RO pump. 
2.  If used set to 4 hours. 
3.  Set duration to 15 minutes. 