User Manual

MAPware-7000 Programming Manual 79
1010-1040, Rev. 02
Database. The Tag Information dialog box appears:
Click the Add button. Under Node Name, click the pull-down box to select the Allen
Bradley driver. For Tag Name, select a unique name for the register (ex: Boiler Temp).
Under Register/Coil Type, use the pull-down box to select Integer Registers. We wish to

right-
We are going to need a tag for a bit that we plan to turn On/Off and we also need an
Let us also create
another register tag that is used when we create a ladder logic program.
For these tags, we want to use t
[Operator Panel] None {-}.
Under Tag Name, enter a name that you want to use for the coil (ex: Boiler Alert).
In the Register/Coil Type field, use the pull-down menu to select Internal Coils.
Under Tag Type, make sure you check the Coil or Bit Addressed Register radio button.

Click the Add button to add this tag to the database.