User Manual
208 MAPware-7000 Programming Manual
1010-1040, Rev. 02
Parameters:
First PLC Tag target location that is used to write RTC values as follows:
Address 0 (Specified by First PLC Tag): Hour (hh) range 0 to 23
Address +1: Minute (mm) range 0 to 59
Address +2: Seconds (ss) range 0 to 59
Address +3: Day of Month (DD) range 1 to 31
Address +4: Month (MM) range 1 to 12
Address +5: Year (YY) range 0 to 99
Address +6: Day of Week (DY) range 1-Saturday
Enable Control Allows tags to control this task. Note: this option is only available if
o Enable if ON, allows task to be executed
o Done HMC7000 sets this coil after successful completion of task. Coil clears
(reset) the next time the task executes.
o Error HMC7000 sets this coil if error occurs during performance of task. Coil
clears (reset) the next time the task executes.
Copy Tag B to Tag A
Description: Copies a value residing in the Tag B register to the target Tag A register.
Parameters:
Tag A: this is the destination address
Tag B: this is the source address
Enable Control: Allows tags to control this task. Note: this option is only available if
configurinare used.
o Enable: if ON, allows task to be executed
o Done: HMC7000 sets this coil after completion of task
o Error: HMC7000 sets this coil if error performing task
Copy Tag to LED
Description: Controls the Function Key LEDS. Use an 8-bit register to turn on/off the LEDS. Each
bit in the tagged register controls an LED. The least significant bit (Bit 0) controls F1 LED, and so
on.
Parameters:
Tag: target location that is read to determine LED position.