Owner's manual

Local Setup Setting
This parameter determines whether the OIT allows you to access Configuration mode. If
this parameter is disabled, you will not be able to enter Configuration mode. Since you
must enter Configuration mode to reprogram the OIT, you will not be able to reprogram
the OIT until the host controller sends a Keyboard control command enabling local setup
again.
Factory Default: Enabled
To modify this parameter using
STEPware-100:
1. Open the Configuration Editor.
2. In the OIT Operational Settings group box, select the Local Setup Enabled check box.
To modify this parameter in
Configuration mode:
1. At Setup Access:, use the OIT’s Period (.) key to enable or disable local setup. Refer
to the Configuration Mode section in this chapter for more information.
To modify this parameter from the
host controller:
1. Use the Keyboard control command. Refer to Appendix A: Control Commands for
more information.
Passwords Setting
This parameter determines the five-digit numeric password used to restrict entry into
Configuration mode. Configuration mode is used to change the OIT’s operating
parameters or to download/upload a project to/from STEPware-100.
When attempting to enter Configuration mode, the OIT prompts you to enter the Setup
Password. If the default setting of “00000” has not been changed, you simply press the
OIT’s ENTER key to access Configuration mode. If the setup password has been changed,
you must enter the correct five-digit numeric password to access Configuration mode.
NOTE:If you forget your password, call Maple Systems Technical Support department at
425-745-3229 for help accessing Configuration mode.
Factory Default: 00000
To modify this parameter using
STEPware-100:
1. Open the Configuration Editor.
2. In the OIT Operational Settings group box, choose the Editor button to open the Password
Editor dialog box.
3. In the Setup text box, enter a five-digit numeric password.
4. Choose the Done button.
To modify this parameter in
Configuration mode:
1. At Setup Password, use the OIT’s numeric keys to enter a five-digit numeric
password. Refer to the Configuration Mode section in this chapter for more
information.
To modify this parameter from the
host controller:
1. This feature cannot be changed from the host controller.
17 MAP450D Operation Manual
1010-0101, Rev. 00