Service manual
13
Step 25. Route the red wire from the eye terminal as shown in the picture to the second GE circuit breaker. Trim off
any excess wire being extremely careful to do the cutting outside of the electronics compartment so that no copper
fragments end up in the compartment. (We placed the electronics compartment’s cover over the space before making
each wire cut.) Attach the end of the red wire to the positive (“+”) terminal of the GE breaker. Place the protective
wire covering along the length of the red wire. Cable strap the wire to hold it in place.
Step 26. Route the black wire from the eye terminal as shown in the picture below to the second GE circuit breaker.
Trim off any excess wire being extremely careful to do the cutting outside of the electronics compartment so that no