Specifications

Note
Some European markets use the 887B power controller which is
electrically the same as the 881B although its physical configuration
is slightly different.
Complete safety and tag-out procedures are explained in the Digital safety
courses listed in Table 1. For maximum safety, always use the following tag-out
procedures:
Turn off site power at the main circuit breaker.
Place a tag-out tag on the circuit breaker.
Connect the power controller power cord to the outlet.
Turn on site power at the main circuit breaker when you have finished with
the installation.
Remove the tag-out tag.
Connect the power controller power cord to the outlet and turn it on.
Turn on all components in the cabinet.
Figure 3–19 shows the 881 power connector configurations and specifications.
Figure 3–19 881 Power Connector Configurations
PLUGS GOING TO WALL OUTLET (FROM CONTROLLER)
120/208V AC 60HZ
30A
3-PHASE
WYE
USED WITH 881-A
POWER CONTROLLERS
220-240/380-415V AC 50HZ
20A OR 16A
3-PHASE
WYE
USED WITH 881-B
POWER CONTROLLER
5-WIRE
NEMA NO. L21-30P
5-WIRE, 4-POLE,
IEC 309
CXO-3551A-TI
3.10 Applying Power
Use the following procedure to turn on the power controller:
1. Ensure that the power on/off switches on all storage devices are in the off
positions. (Refer to Figure 3–16.)
2. On SA7x enclosures, ensure that the front panel drive power switches are in
the off positions.
3–28 Installing a Storage Array