Specifications

RA7x/SA7x Pocket Reference Guide 51
67—Write Failure
Error Description: One of five possible conditions
occurred during the diagnostic write section of the test.
The five conditions are:
Invalid sector number
Expired sector timer
Expired write sector timer
Incorrect write sector
Write diagnostic failure
FN: F9—inv.dgn.wsn.—invalid diagnostic write sector
number
FN: FB—inv.dgn.wsf.—invalid diagnostic write sector
fault
FN: FC—exp.dgn.wrs.—expired diagnostic write sector
timer
FN: FD—inc.dgn.wrs.—incorrect diagnostic write sector
number
Most Probable Cause: ECM, HDA
85—External RAM Failure
Error Description: If, during any data verification
process, the data stored in the processor external
RAM location does not match the data that was written
to that location, the test is terminated and this error is
reported.
FN: E3—inv.dat.mem.—invalid external static RAM
memory
Most Probable Cause: ECM