Specifications
40 RA7x/SA7x Pocket Reference Guide
17—Invalid or Inconsistent Parameters
Error Description: One or more of the parameters
sent by the controller as part of the level 2 command is
invalid or inconsistent.
FN: 18—inv.gbd.cyl.—invalid guard band cylinder
access
FN: AE—inc.sct.fmt.—incorrect drive sector format
FN: B8—inv.lv1.grp.—invalid level 1 group select
(head) number
FN: C2—inv.sct.fmt.—invalid drive sector format
FN: C3—inv.dmr.num.—invalid diagnose memory
region number
FN: C4—inc.dmr.num.—incorrect diagnose memory
region number
FN: C6—inv.top.disc.—invalid topology disconnect
FN: C7—err.flg.astd.—generic error bit flag asserted
FN: C9—inv.lv1.num.—invalid error recovery level
number
FN: CB—inv.grp.num.—invalid group select (head)
number level 2
FN: CC—inv.cyl.adr.—invalid cylinder address number
level 2
FN: CD—inv.dgn.cyl.—invalid diagnostic cylinder
access
FN: D0—inv.rmr.num.—invalid read memory region
number
FN: D1—inv.rmr.ofst.—invalid read memory region
offset
FN: D3—inv.wmr.byct.—invalid write memory region
byte count
FN: D4—inv.wmr.num.—invalid write memory region
number
FN: D5—inv.wmr.ofst.—invalid write memory region
offset
FN: D6—inv.wmr.siz.—invalid write memory region size
Most Probable Cause: ECM, SDI controller, SDI
cable