Specifications
RA7x/SA7x Pocket Reference Guide 37
0A—SDI Command Opcode Parity Error
Error Description: The opcode in a level 2 SDI
command was received with incorrect parity. The
opcode byte must be even parity.
FN: B3—inc.opc.prty—incorrect command opcode
parity
Most Probable Cause: ECM, SDI controller, SDI
cable
0B—Invalid Opcodes
Error Description: One of two conditions have been
detected:
• The opcode received in the level 2 command was
not one of the 16 possible opcodes.
• The opcode received in the level 2 command was
one of the 16 possible opcodes, but the opcode
parity was wrong.
FN: B2—inv.cmd.opcd.—invalid command packet
opcode
FN: B7—inv.lv1.opcd.—invalid level 1 command
opcode
Most Probable Cause: ECM, SDI controller, SDI
cable
0C—Command Length Error
Error Description: The byte count for any given level
2 command is incorrect.
FN: A3—inv.cmd.byct.—invalid command packet byte
count
FN: B1—inv.cmd.byct.—invalid command packet byte
count
FN: B6—inc.lv1.byct.—invalid level 1 command packet
byte count
Most Probable Cause: ECM, SDI controller, SDI
cable