Installation guide

C.2 Conversion Procedure
Install the 70-inch DSSI cables (BC21R–5L) where necessary to complete the
bus connections to the Sx300 I/O panel:
1. Connect one end of the 70-inch DSSI cable to the DSSI connector on the
rear of the Sx72 storage enclosure or magazine tape subsystem.
2. Install the other end to the appropriate port on the Sx300 I/O panel. See
Figure C–7.
Connect the appropriate number of 108-inch DSSI cables (BC21Q–09) to all the
newly installed 70-inch DSSI cables on the Sx300 I/O panel.
Next, connect the other end of the 108-inch DSSI cables to the appropriate
DSSI connector on the system I/O panel.
Note
If you have not changed the KFMSA module DSSI ID numbers in
the other host system to 6, do so at this time. Do NOT attempt to
connect the 108-inch DSSI cables to this host system until the DSSI ID
numbers have been changed. Refer to the KFMSA Module Installation
and User Manual (EK–KFMSA–IM).
Refer to Table A–5 for cabling diagrams of the single-host and dual-host
configurations.
C.2.4 Labeling the Cables
This section describes the steps to label correctly the cables for the VAX 6000
series system, the Sx300 storage array, and its Sx72 storage enclosures and
tape magazine subsystems.
At this point, all steps in the previous sections must be complete.
Converting a Single-Host Configuration to a Dual-Host Configuration C–11