Installation guide

C.2 Conversion Procedure
C.2.2 Split-Bus to Through-Bus Conversion
Use the following steps only if you are converting an Sx72 storage enclosure
in position 3 or 5 of an Sx300 storage array from single-host to dual-host
configuration. Sx72 storage enclosures in position 3 and 5 must be converted to
through-bus mode.
CAUTION
Maintain ESD precautions at all times. Before performing the following
steps, locate the ESD strap in the ESD pouch at the bottom of the front
door.
To maintain stability, extend only one Sx72 storage enclosure or
magazine tape subsystem on the slide mounts at a time.
1. Remove the OCP by firmly grasping the right and left side of the OCP and
pulling the OCP straight off.
2. Loosen the four captive slide assembly screws. At the rear, push the inner
assembly out until the drawer locks in the service position.
Note
Do NOT completely remove the Sx72 inner drawer assembly from the
extrusion tube.
3. Reconfigure the transition termination module (TTM) for through-bus mode
by first moving the small black jumper to the through-bus terminals. Then
move the cable connector from J3 to J5, and the cable connector from J2 to
J4 as shown in Figure C–3.
4. Push the Sx72 inner assembly back into the extrusion tube. To prevent
pinching any cables, be sure that all cables are dressed correctly.
5. Tighten the four captive slide assembly screws.
6. Set the DSSI ID number switches behind the OCP front door of positions
3 and 5 to match those in positions 1, 2, 4, and 5. See Figure C–4 and
Table C–1.
7. Replace the OCP by lining up the taps on the back of the OCP with the
slots on the front of the storage enclosure. Firmly press the right and left
side of the OCP.
C–6 Converting a Single-Host Configuration to a Dual-Host Configuration