Installation guide

5.1 Steps to Install
Table 5–3 DSSI ID Switch Settings (SF7x Only)
SF1, SF2, SF4, SF5
1
Left Rear (LR)
Left Front (LF)
Right Front (RF)
Right Rear (RR)
001
010
011
100
SF3, SF6 in split bus mode (Single-Host Only)
1
Left Rear (LR)
Left Front (LF)
Right Front (RF)
Right Rear (RR)
101
110
110
101
1
The switch settings for OCPs in these positions are 0 = down and 1 = up.
CAUTION
Observe all ESD precautions and procedures.
An antistatic wrist strap is inside the front and rear doors.
4. Install the OCP (see Figure 5–6).
Note
Make sure that the power if off to the enclosure.
Make sure that ALL the buttons are in the out position.
5. At the front of the SF7x enclosure, make sure that all four (4) drive dc
power switches are out (see Figure 5–7).
6. At the rear of the SF7x enclosure, make sure that the ac power switch is in
off or in the 0 position (see Figure 5–8).
Installing the SF7x Storage Enclosure in an Sx300 Storage Array 5–13