Installation guide

5.1 Steps to Install
5.1.2 Where to Install the SF7x Storage Enclosure
The SF7x storage enclosures install in numerical order. Refer to Chapter 3.
SF7x storage enclosures could occupy positions 1, 2, 3, 4, 5, and 6 .
In split-bus mode, the following drives are part of the same DSSI bus (note
that split-bus mode is supported in the single-host configuration only):
1. Four drives of SF1 with the two left drives SF3
2. Four drives of SF2 with the two right drives SF3
3. Four drives of SF4 with the two left drives of SF6
4. Four drives of SF5 with the two right drives of SF6
Note
In a stripeset configuration, all SF7x storage enclosures must be in
split-bus mode. Each DSSI bus is connected to two ISEs in each SF7x
enclosure. One KFMSA module is required for each SF7x storage
enclosure.
All SF7x storage enclosures must be in through-bus mode when the Sx300
storage array is in the dual-host configuration:
1. Four drives of SF1
2. Four drives of SF2
3. Four drives of SF3
4. Four drives of SF4
5. Four drives of SF5
6. Four drives of SF6
5.1.3 Checking the System Configuration Sheet
Locate the system configuration sheet. If you cannot locate this sheet or if the
one that is available is either not filled out or filled out incorrectly, fill one out
immediately.
Refer to the KFMSA Module Installation and User Manual (EK–KFMSA–IM)
for an explanation of this sheet and how to fill it out.
Installing the SF7x Storage Enclosure in an Sx300 Storage Array 5–5