Specifications
30259-0-0212 Page 39
START UP AND ADJUSTMENTS
A. Withmainelectricalpowertothereplaceturnedoff,install4
AAsized1.5Vbatteriesintotheremotereceiver.Theremote
receiver is located inside the replace, mounted to the top
oftheblowerhousingandsecuredwithhookandlooptape.
SeeFigure70.Setupreceiverandremoteperinstructionson
pages41-46.
RECEIVER LOCATION
ADJ. LEARN
REMOTE ONOFF
Figure 70
B. Turnonthemainelectricalpowertothereplaceandturnthe
mainburnerswitchtotheONposition.SeeFigure71.Verify
powerisonbycheckingifthereispowertothecircuitboard.
Iftheunithaspower,thepowerlightwillbeilluminated.
Figure 71
C. Turnonthemaingassupply.
D. Turnbothburnerswitchesontoigniteboththefrontandrear
burners.BurnerswitchesmustremainintheONpositionfor
the remote to function. See Figure 72.
E. TheDisplayPanelboardshouldbeenergized,andthepower
lightwillbeilluminated.
Sequence of Operations – Front and Back Burners
1. The Display Panel will be energized, and the lights for the
frontburnerandbackburnerwillash.
2. Theinducerwillactivateimmediatelyandwillprovethepres-
sure switch within 16 seconds. This will initiate the ignition
sequence.
3. Therearigniter(HSI)willenergizeandstarttoglowred.
4. Within3to5seconds,thegasvalvewillopenandignitethe
rearburner.Theamesensorwillverifytheameispresent
within2to5seconds.
5. Theigniterfor the frontburner willenergize5 to7 seconds
aftertheameisestablishedontherearburner.
6. Thegasvalvewillopentoignitethefrontburnerwithin3to
5seconds.Theamesensorwillverifytheameispresent
within2to5seconds.
7. AstheMantiswarmsup,thecirculatingblowerwillactivate,
startingonLowspeed.TheLowBlowerL.E.D.willlightwhen
theblowerturnson.
8. AstheMantiscontinuestooperate,thespeedofthecirculat-
ingblowerwillincrease,andtheL.E.D.forMediumandHigh
willappear.
FRONT
BURNER
SWITCH
REAR
BURNER
SWITCH
ECONOMY
DISPLAY
BUTTON
= OFF
=ON
Figure 72
CAUTION
When switching from one burner to the other burner, be
sure to rst turn “ON” the desired burner before turning
“OFF” the burner that is operating. Failure to follow this
sequence may result in the replace needing to be reset.
See page 49 - Resetting the Fireplace.