Specifications

30259-0-0212 Page 37
START UP CHECK LIST
1. Verify the gas line service does not exceed 10.5 in. w.c.
and is not below 5.0 in. w.c. for natural gas, nor exceeds
13.0in.w.c.orisbelow11.0in.w.c.forLPgas.
2. Checkand inspect the replace for gas leaks.In the event
ofgasleaks,cutoffthegassupplytothereplaceimmedi-
atelyandcallyourgassupplier.Verifythegaslinehasbeen
purged.
3. Verifythatallexhaustandinletairpipesareunobstructedand
properlyjoined.
4. Visually verify the burners are free of dust and debris.
SeeFigures56and67.
5. Check and verify that logs are place correctly. See pages
33to35.Thelogsmustbeinthecorrectpositionorthere-
placewillnotoperatecorrectly.
DO NOT light replace without the logs installed, the replace
will not operate properly.
6. Verifythatallpanelsaresecuredinplaceandthattheglass
assemblydoorhasbeenlockedinposition.
7. VerifythetwoburnerswitchesareintheOFFpositionbefore
applyingpowerandthemainpowerswitch.
8. Afterverifyingandcheckingalltheabovepoints,proceedto
lighting instructions. Refer to Page 38.
9. Verifythatthepolarityoftheconnectionsarecorrectandthe
linevoltagepowerleadsaresecure.
Note:Ifusingasurround,verifyitisinstalledpertheinstruc-
tionsincludedwiththekit.
WARNING
BEFORE OPERATING THIS Fireplace, CARE-
FULLY READ THE FOLLOWING.