Specifications
30259-0-0212Page 32
GAS CONNECTION INSTALLATION
PUSH IN PLUG
ACCESS PLATE
CAUTION
The gas supply line to the replace must be installed
under conditions which will allow for easy removal
of the replace from its location for servicing of the
replace. For replace insert installation, incorporate
a loop into the exible gas line.
Under no circumstances should the gas supply line
to the replace be installed in a way that would pre-
vent the replace from being serviced or inspected.
GAS SUPPLY LINE TO FIREPLACE
1. Pullthefactoryinstalledexiblegaslinethroughtheholein
thebackpanel.SeeFigures54and55.
2. Connectthegassupplylinetoexiblegashose.Ensurethat
exiblegashoseisnotkinkedafterttinggassupplyline.Any
excessexiblelinecanbepushedbackintothereplace.
3. Place rubber grommet that is supplied in hardware packet
overtheexiblegaslineandsecureintheholeinthebackof
thereplace.
Gas Connection - In-Wall Units - Fireplace Mantis ONLY
1. Removethe accessplate onthe leftside ofthe cabinetby
removing three screws as shown in Figure 56. Put the screws
aside.
2. Pushthefactorysuppliedexiblegaslinethroughtheaccess
holeontheside.
3. Remove the knockout from the access plate and insert the
exiblegaslinethroughthehole.
4. Securetheaccessplatetothecabinetwiththreescrewsre-
movedinStep1.
5. Aplastic pushinplug is suppliedinthe hardware package,
inserttheplugintothe1-3/8inchholeinthebackoftheunit.
6. Inserttherubbergrommetintotheholeintheaccessplateto
protecttheexiblegasline.
Figure 54 - Fireplace Mantis
Figure 55 - Bay Window Mantis
Figure 56
Gas Connection, Fireplace Mantis In-Wall Units
FLEXIBLE GAS
LINE