Specifications

30259-0-0212 Page 19
DIRECT VENT COLINEAR VENT EXAMPLES
Figure 17
Indirectventapplications,theminimumdistancebetweenthetwo
pipesis3inchesandthemaximumdistanceis24inches.Theue
exhaustandairinletcanbeterminatedwitheitheraPTraportwo
90°elbowsasshowninFigures13,14,15,19and20.TheVerti-
calTerminationCapshownonpage13(PartnumberPVVTC)can
alsobeused.
Figure 18
In both vertical and horizontal colinear direct vent applications,
acolineartransitionplatemodelPVCTcanbeusedtominimize
clearancesbetweenintakeandexhaustpipes.
For exhaust and intake air, cap pipes with any of the following:
Vertical termination cap (model #PVVTC), PTrap,or two 90º el-
bows.Whentransitionplate(modelPVCT)isused,twotermina-
tioncaps(modelPVVTC)mayNOTbeused.
Note:Iftransitionplate(modelPVCT)isused,themeasurement
forcentertocenterofthepipeswillbe2.5”.Ifthetransitionplate
(modelPVCT)isnotused,themeasurementforcentertocenter
ofthepipescanbe3”to24”maximum.
MODEL PVCT
12” MIN.
EXTERIOR GRADE
CO-LINEAR DIRECT VENT ADAPTER
MODEL PVCA
SINGLE FLUE ADAPTER
MODEL PVVK-FC